hendiCtrl.py is now import-only. The new CLI app exposes serial
port/baudrate, version/capability info, converter test, heater test,
and firmware update as separate flags, instead of one fixed script.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01GpePKZiEZWbGo9HrfuML6U
PlantFactory.create() no longer takes plant_name; sim vs real is derived
from Heater.type. StirrerFactory is wired from Stirrer.type. HeaterFactory
registry key lowercased to "hendi" to match config. Controller.plant_name
removed from both config templates.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
On KeyboardInterrupt, brewpi.py cancels all asyncio tasks (letting
HeaterTask's `with device.open()` finally block run), then calls
heater.close() as belt-and-suspenders before closing the event loop.
On shutdown HeaterHendi.activate(False) now sets the switch to 0 instead
of disabling remote control, so the Hendi stays in remote mode at 0 W
rather than dropping back to its local panel state. HendiCtrl.close()
does the same (setSwitch(0)) then closes the serial port.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
All four name-dispatch factories repeated the same if/elif lazy-import
pattern. Replace with a ComponentFactory base class holding a callable
registry and a _lazy() helper for the common import-and-construct case.
PlantFactory is an orchestrator, not a dispatcher, and is left as-is.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Tqxrk8uj4M3w3d3eXm3xK8