MessageDispatcherSync gains an optional on_connect_changed(bool)
callback, fired from the websocket client's background loop once the
connection is actually live/lost, so the button only flips state on a
real connection change rather than optimistically on click.
Start/Pause/Stop on the toolbar were never about the websocket
connection - Start now does nothing until that's wired to its own
purpose, and connecting is its own explicit action next to the host
text entry.
Adds a static forecast plot to the (previously empty) Automatic tab,
showing the planned temperature course derived from a schedule's
declared ramp rates and hold durations alone (no plant/controller
model - just how long the schedule itself says each step takes).
The client now requests the schedule via Download right after
connecting, routing the reply to the forecast instead of a save
dialog since sud_download_path is only set for the user-initiated
download. SudTask also echoes the just-applied document back after a
successful Upload, so editing the schedule refreshes the forecast
without an extra round trip.
Reformats it to json.dump()'s standard 2-space-free, ensure_ascii
output (from exercising the new upload feature against the real
schedule) and adds the matching downloaded copy. No schedule content
changed.
Drop dark_background in favor of a plain white figure, matching
demo_sud's blue/red ist/soll color convention. Add faint major/minor
gridlines, drop the top/right spines, and use label_outer() so only
the bottom subplot repeats x tick labels across the shared time axis.
Embeds a dark-themed matplotlib canvas (3 stacked strip charts: theta
ist/soll, heatrate ist/soll, heater power_set/power_eff) in a new Plot
tab, sampled once per second from the latest websocket-received values.
HeaterTask now also emits a PowerSet message (the pre-discretization
target power) alongside the existing Power (effective) message, since
the GUI had no way to see the set-point side of figure 1's bottom plot
otherwise.
Adds File menu actions to save the running Sud's schedule to a local
sud.json and to replace it from one, via the Sud websocket channel's
new Download/Upload messages. File dialogs are opened up front on the
GUI thread; the actual read/write happens off the websocket recv
callback, which runs on a worker thread and must not touch Qt itself.
main_window.py is regenerated from brewpi.ui via pyuic5 5.15.11, which
also picks up an unrelated pre-existing drift (the default URI had
fallen out of sync with the .ui source).
Sud.download() returns the on-disk document; Sud.upload() validates,
persists, and resets the schedule, refusing mid-brew or malformed input
so the current schedule is never left half-applied.
Both blocks were nearly identical (config.json.sim's differing M and
unused gain key being the only divergence), so there's no need for
per-config tuning here. DEFAULT_PLANT_PARAMS in brewpi.py now feeds
both the real Pot plant and the temperature controller's
Smith-predictor model. No demo scripts read these config keys, so
nothing else needed updating.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01CgR9tPaSzFkAwRAUyeaaCD
grain_mass and water_mass now live on each step (defaulted from
default.step) instead of being fixed for the whole brew, since both
change over a mash (malt going in, water boiling off).
Sud.derive_plant_params() takes them as arguments so it can be
recomputed per step; the demo re-applies the resulting M/C to both the
real plant and the controller's Smith-predictor model on every step
change via the new Pot.set_thermal_params()/
TempController.set_model_params().
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01CgR9tPaSzFkAwRAUyeaaCD
Steps now declare a "ramp" or "hold" key instead of a flat "type", and
unspecified fields (including nested stirrer settings) fall back to a
new top-level default.step structure. Stirrer config is now
interval_time/on_ratio, mapping directly onto AStirrer's cycle
time/duty cycle instead of separate on/off durations. Update
components/sud.py, tasks/sud.py, the Sud demo, sude/sud_0010.json, and
the README to match.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01CgR9tPaSzFkAwRAUyeaaCD
Add Sud.derive_plant_params(), which combines pot_mass/pot_material/
grain_mass/water_mass into a single lumped (mass, specific heat) pair
using approximate specific-heat constants for water, grain, and (by a
small material lookup table) the pot itself. demo_sud.py now builds
its plant_params from this instead of hardcoded C/M values, keeping
L/Td as the only manually-tuned plant parameters.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Now that duration is correctly read as seconds, bump the sample
schedule's hold steps from the placeholder 30-40s to more realistic
200-400s.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
_advance() multiplied "duration" by 60, treating it as minutes;
stirrer_speed (percent) and stirrer_time_on/off (seconds) were already
handled correctly with no conversion. Also fix the README's "duration
minutes" wording to match.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
sude/sud_0010.json moved from a list of combined ramp+hold+wait
"Rasten" with global stirrer constants to a flat "schedule" list of
explicit {"type": "heat"|"hold", ...} steps, each carrying its own
stirrer_speed/stirrer_time_on/stirrer_time_off and an optional
user_wait_for_continue (+ user_message).
- components/sud.py: Sud now tracks the current `step` instead of
`rast`; "heat" steps enter RAMPING (advanced externally via
temp_reached()), "hold" steps enter HOLDING and count down
`duration` minutes (0 if omitted). Either step type can pause in
WAIT_USER via user_wait_for_continue, surfaced through the new
user_message attribute.
- tasks/sud.py: SudTask only pushes theta_soll/heatrate_soll on
"heat" steps, converts each step's stirrer_time_on/off into a
duty_cycle/cycle_time on every step change (replacing the old
state-based RAMPING/HOLDING stirrer switching), and broadcasts
user_message changes. Stirring is now fully schedule-driven instead
of implicitly stopped on WAIT_USER/DONE (DONE still stops it, since
there's no step left to read settings from).
- scripts/demos/sud/demo_sud.py: mirrors the same step-driven wiring.
- README's Mash schedules section rewritten for the new schema.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Drop the now-stale "config.json.templ/.sim still carry dead
Model.kn/Plant.kn keys" note (they were deleted), note that Pot now
always starts at theta_amb (no separate initial-temp param) and that
dropping the gain (efficiency) factor entirely is a partial realism
regression, not just a fix. Point the config-validation item at the
gain key that's still dead in config.json.sim. Also update demo_sud.py
to match the Pot params Pot.__init__ actually reads.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
[Pot] - removed the gain (efficiency) factor and the separate
"theta" initial-temperature param; Pot now starts at theta_amb and
set_power()/get_power() operate on p_in directly. Added
set_ambient_temperature() for live ambient updates. Dropped the
now-unused "theta"/"gain" keys from Model/Plant in config.json.sim
and config.json.templ (also fixes a JSON syntax error in
config.json.templ: trailing commas left over after removing "gain"
made Model/Plant fail to parse).
[Sensor] - fix missing space in TempSensorSim.temperature()'s
offset/variance expression (cosmetic, no behavior change).
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
It existed since the matplotlib-demo relocation but was never added
to the architecture listing.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Drives a real Smith-predictor TempController, Pot, HeaterSim, and
StirrerSim through sude/sud_0010.json end-to-end (mirroring brewpi.py's
wiring, including the model/plant power-discretization mismatch and
tasks/sud.py's stirrer-switching rules), auto-confirming waitForUser
pauses so it completes unattended. Plots theta/heatrate (actual vs.
target), heater power_set/power_eff, Sud state, rest index, and
stirrer speed/duty cycle over time.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
brewpi.py had a dead -m/--model CLI arg and sude/*.json schedules were
pure data with no code to drive them, despite the README documenting
them as if they were already wired up.
Add components/sud.py's Sud, which loads a sude/*.json schedule and
steps through its Rasten (ramp -> hold -> optional wait-for-user ->
next rest), and tasks/sud.py's SudTask, which drives the temperature
controller's theta_soll/heatrate_soll from the current rest and
switches the stirrer between continuous (ramping) and intermittent
(holding, via stirrSpeedRast/stirrDutyRast/stirrCycleTime) operation.
Exposes progress on a new "Sud" WebSocket channel and accepts
Start/Confirm commands. Enabled via a new optional top-level "sud"
config key (see config.json.templ/.sim).
"Reached target" is detected via abs(theta_ist - theta_soll_set) <
tolerance rather than tc.state == HOLD, since the latter can still
read HOLD left over from the previous rest for one tick after a new
target is pushed (tc.state only updates on the controller's own,
independently-scheduled process() tick).
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Pid.scale(k) set self.k as persistent state, mutated from outside the
class and never reset in reset(), so a stale scale factor could survive
a state-transition reset. Replace it with a plain scale=1.0 argument on
Pid.process(), and have temp_controller.py/temp_controller_smith.py
compute the heat-rate-overshoot compensation factor themselves and pass
it through process_pid() each tick instead of mutating pid_hold's state.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
on_temp_ist_changed/on_rate_ist_changed printed every update in
addition to forwarding it over the WebSocket, spamming stdout once
per controller tick.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
brewpi.py passed a literal 20 as theta_amb to Pot, and
temp_controller_smith.py's two internal Pot models (and every demo's
Pot/TempController instantiation) silently relied on Pot's default of
20 instead. Add a top-level ambient_temperature key to
config.json(.templ/.sim), thread it through brewpi.py into both the
real plant and the Smith predictor's models via a new theta_amb param
on TempController, and make the demos pass it explicitly too.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
The unconditional p_loss/theta_amb/temp prints (left over from the
heat-loss-units fix) ran every tick, spamming stdout in both the
server and every demo script. Drop them and check off the matching
TODO.md item.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Both TODO.md backlogs and the README's architecture section still
described the Kalman-filter/heat-diffusion design that's since been
replaced by the delay-line Pot model and Kalman-free Smith predictor.
Check off the items that rewrite already fixed (heat-loss units,
transport delay vs. single-pole lag, three-Kalman-tuning), note how
the kn/sensor-noise item was resolved differently than proposed, and
add newly-spotted issues: brewpi.py wiring set_model_power
unconditionally (breaks pid_type "Normal"), kalman.py being dead code
in production, stale Kalman/kn keys in the config templates, and
debug print()s left in Pot.process().
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
tc_constants.py only held States and DEFAULT_THRESHOLDS, both used
exclusively by temp_controller_base.py and its subclasses; fold them
into temp_controller_base.py directly and drop the now-empty module.
Also drop heat_diffusion.py, unused since pot.py switched to the
delay-line model, and the matching dead import in pot.py.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
[Sensor] - replace TempSensorSim's hardcoded k_noise with configurable
temp_offset/variance, accept **kwargs on Max31865 too so both sensors
share a constructor signature usable from TempSensorFactory.create()
[Temp Controller] - low-pass filter the backward-difference heat-rate
estimate (alpha=0.1) in both temp_controller.py and
temp_controller_smith.py instead of using the raw, noisy derivative
[Pot] - drop kn from demo_pot.py's params, matching the unused-field
removal already made to pot.py itself
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
[brewpi] - drop trace vars for the dtheta_ist_* attributes removed
when temp_controller_smith.py dropped Kalman filtering
[Pot] - drop unused kn field (never read since the noise-injection
code that used it was dropped)
[GUI] - default WS connection to ws://localhost:8765
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
temp_controller_smith.py still relied on Kalman filtering and Pot's old
get_temperature_intermediate(), both removed by the recent Pot/Kalman
simplification. Rebuild it using two Pot model copies (zero-delay and
delayed) and the same backward-difference heat rate as temp_controller.py,
combined into the classic Smith correction:
theta_ist = theta_model_fast + (theta_plant - theta_model_delay).
Also fix set_model_power() never being called, so the internal model
actually receives the controller's power output, and fill in
demo_temp_controller_smith.py to exercise it end-to-end with an extra
plot of plant vs. fast-model vs. delayed-model temperature.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
temp_controller.py, temp_controller_smith.py, and kalman.py imported
matplotlib at module level just to support eyeballed-plot __main__
blocks, coupling the live server's import graph to a GUI plotting lib
it never uses at runtime. Relocate those demos (and kalman_eval.py) to
scripts/demos/pid/ and strip the now-unused imports/__main__ blocks
from the production files.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Review of pot.py found a likely root cause for sim-vs-real control
mismatches: the heat-loss term carries the wrong units, masking
ambient cooling in simulation. Also notes the dropped sensor-noise
term, hardcoded ambient temp, and lag-vs-dead-time modeling gap.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
THRESH_HOLD_IDLE/HOLD_HEAT/IDLE_HEAT/IDLE_HOLD/HEAT_HOLD/HEAT_IDLE in
tc_constants.py were hardcoded module-level constants shared by every
controller instance, so tuning the IDLE/HOLD/HEAT hysteresis required
a code change.
Replace them with DEFAULT_THRESHOLDS plus an optional
TempCtrl.Thresholds config section, merged at construction time in
TempControllerBase.__init__ so configs that omit the section keep
behaving exactly as before. Documented the new section in
config.json.templ; left config.json.sim without it to exercise the
default-fallback path.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Tracks open issues from a review that weren't fixed as part of this
branch's Smith-predictor and dedup work: non-configurable FSM
thresholds, Pid.scale()'s gain-scheduling hack, shared Kalman tuning
across the Smith controller's 3 filters, matplotlib imported at
module level in production code, no automated tests, and unchecked
config access.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Pure rename of the pyuic5-generated UI module plus its one import
site in brewpi_gui.py; regenerated from brewpi.ui, no content changes.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
PyQt5.Qwt isn't pip-installable; it only existed via the apt package
python3-pyqt5.qwt, so pip-installing client/requirements.txt's plain
PyPI PyQt5 always crashed with "No module named 'PyQt5.Qwt'".
Qwt was only used for 3 QwtSlider widgets (Slider_temp_soll,
Slider_pwr_soll, Slider_speed_soll). Swap them for stock QSlider in
brewpi.ui, regenerate brewpi_win.py via pyuic5, and update
brewpi_gui.py's setLowerBound/setUpperBound calls to QSlider's
integer-only setMinimum/setMaximum. The GUI now runs from a plain
`pip install -r client/requirements.txt` venv with no system PyQt5
packages required.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
TempControllerBase no longer threads model_params through (only the
Smith subclass needs it, for its own Pot model and Kalman filters).
Enable the Smith predictor's actual delay-compensated error term
(theta_err now uses theta_ist_plant - theta_ist_model_delay +
theta_ist_model instead of the plain plant reading), which is the
correction this controller is named for.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Both controllers had nearly identical process_fsm(), process_pid(),
and all getters/setters; only Kalman/model setup and process()
genuinely differed, and the duplication had already drifted (the
Smith variant resets model state on entering HEAT, the plain one
didn't).
Add TempControllerBase with the shared logic and three small hooks
(init_kalman, on_state_entered, post_pid) subclasses use to plug in
their own Kalman/model behavior. Each subclass now contains only what
makes it different.
Also fixes a latent crash: TempController's constructor only accepted
(dt, params), but PidFactory/brewpi.py always call it with a third
model_params arg, so pid_type "Normal" would have raised TypeError.
The shared base's model_params=None default fixes this. Also
initializes the Smith controller's trace attributes in __init__
instead of leaving them undefined until the first process() call.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
ws/client/ws_client.py calls websockets.connect(uri, loop=self.loop),
which the current websockets release (16.0) no longer accepts. Pin to
the same version already used server-side. PyQt5.Qwt, also required
by client/brewpi_win.py, isn't pip-installable and must come from the
python3-pyqt5.qwt system package.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>