Mirrors components/pid/pid.py's own Pid.set_params() pattern: params/
thresholds start out None, and set_params() configures pid_hold/pid_heat/
pid_cool from them. process()/process_fsm() fail naturally (TypeError on
None) if called before set_params() - same as Pid.process() already does -
rather than a new bespoke check. Updates all callers (server/brewpi.py,
SudForecastEstimator, and the pid/sud demo scripts) to call set_params()
right after construction.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01DkkuG48uHFCGKe6dPSERFk
Pot.__init__ now only takes dt; set_plant_params() and set_ambient_temperature()
must be called before process(), which now raises RuntimeError if either is
missing instead of silently computing on whatever the constructor happened to
default to. set_ambient_temperature() only seeds the plant's starting
temperature the first time it's called, so changing ambient mid-run still
can't clobber an in-progress simulated temperature. Updates all callers
(server/brewpi.py, TempController(Smith)'s two internal models,
SudForecastEstimator, and the plant/pid/sud demo scripts) to call the setters
right after construction.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01DkkuG48uHFCGKe6dPSERFk
IDLE conflated two unrelated things: "controller disabled" and "needs
to cool, which this heat-only actuator fakes via zero output." Split
them apart:
- IDLE now means disabled only - the FSM forces it whenever
enabled=False, regardless of the temperature gap, and process_pid()
zeroes y for it same as before.
- New COOL state (mirroring HEAT) takes over the negative-diff case,
with its own pid_cool (separate "Cool" gains, alongside Hold/Heat)
instead of reusing pid_rate. Its output can legitimately be negative
- it's the actuator (tasks/heater.py's actor(), already max(0, ...))
that clamps it to 0 because *this* plant (Pot) can only heat. A
plant with real cooling capability could one day honor it directly.
- Thresholds renamed accordingly (HoldIdle->HoldCool, HeatIdle->
HeatCool, new CoolHold/CoolHeat); config.json/.sim/.templ and the
hand-rolled ctrl_params in scripts/demos/pid/ and demo_sud.py
updated with a "Cool" params section (mirrors "Heat" for now, since
there's no real cooling actuator to tune against yet).
Also fixes a regression in demo_sud.py/the other PID demos: none of
them ever called set_enabled(True), so since enabled defaults to
False they never drove the heater at all - only caught because this
change's demo_sud.py re-run got stuck in RAMPING forever.
New lineEdit_ambient next to the host/connect row - type a value and
press Enter to send {"System": {"AmbientTemp": ...}}. The server now
has a recv handler for the System channel (previously send-only):
updates the real Pot's ambient temperature and, where the controller
has an internal model (Smith), its model Pots too (new
set_ambient_temperature() on TempControllerSmith), then echoes the new
value back so the status bar label and entry itself stay in sync.
grain_mass and water_mass now live on each step (defaulted from
default.step) instead of being fixed for the whole brew, since both
change over a mash (malt going in, water boiling off).
Sud.derive_plant_params() takes them as arguments so it can be
recomputed per step; the demo re-applies the resulting M/C to both the
real plant and the controller's Smith-predictor model on every step
change via the new Pot.set_thermal_params()/
TempController.set_model_params().
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01CgR9tPaSzFkAwRAUyeaaCD
Pid.scale(k) set self.k as persistent state, mutated from outside the
class and never reset in reset(), so a stale scale factor could survive
a state-transition reset. Replace it with a plain scale=1.0 argument on
Pid.process(), and have temp_controller.py/temp_controller_smith.py
compute the heat-rate-overshoot compensation factor themselves and pass
it through process_pid() each tick instead of mutating pid_hold's state.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
brewpi.py passed a literal 20 as theta_amb to Pot, and
temp_controller_smith.py's two internal Pot models (and every demo's
Pot/TempController instantiation) silently relied on Pot's default of
20 instead. Add a top-level ambient_temperature key to
config.json(.templ/.sim), thread it through brewpi.py into both the
real plant and the Smith predictor's models via a new theta_amb param
on TempController, and make the demos pass it explicitly too.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
tc_constants.py only held States and DEFAULT_THRESHOLDS, both used
exclusively by temp_controller_base.py and its subclasses; fold them
into temp_controller_base.py directly and drop the now-empty module.
Also drop heat_diffusion.py, unused since pot.py switched to the
delay-line model, and the matching dead import in pot.py.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
[Sensor] - replace TempSensorSim's hardcoded k_noise with configurable
temp_offset/variance, accept **kwargs on Max31865 too so both sensors
share a constructor signature usable from TempSensorFactory.create()
[Temp Controller] - low-pass filter the backward-difference heat-rate
estimate (alpha=0.1) in both temp_controller.py and
temp_controller_smith.py instead of using the raw, noisy derivative
[Pot] - drop kn from demo_pot.py's params, matching the unused-field
removal already made to pot.py itself
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
temp_controller_smith.py still relied on Kalman filtering and Pot's old
get_temperature_intermediate(), both removed by the recent Pot/Kalman
simplification. Rebuild it using two Pot model copies (zero-delay and
delayed) and the same backward-difference heat rate as temp_controller.py,
combined into the classic Smith correction:
theta_ist = theta_model_fast + (theta_plant - theta_model_delay).
Also fix set_model_power() never being called, so the internal model
actually receives the controller's power output, and fill in
demo_temp_controller_smith.py to exercise it end-to-end with an extra
plot of plant vs. fast-model vs. delayed-model temperature.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
temp_controller.py, temp_controller_smith.py, and kalman.py imported
matplotlib at module level just to support eyeballed-plot __main__
blocks, coupling the live server's import graph to a GUI plotting lib
it never uses at runtime. Relocate those demos (and kalman_eval.py) to
scripts/demos/pid/ and strip the now-unused imports/__main__ blocks
from the production files.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
TempControllerBase no longer threads model_params through (only the
Smith subclass needs it, for its own Pot model and Kalman filters).
Enable the Smith predictor's actual delay-compensated error term
(theta_err now uses theta_ist_plant - theta_ist_model_delay +
theta_ist_model instead of the plain plant reading), which is the
correction this controller is named for.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Both controllers had nearly identical process_fsm(), process_pid(),
and all getters/setters; only Kalman/model setup and process()
genuinely differed, and the duplication had already drifted (the
Smith variant resets model state on entering HEAT, the plain one
didn't).
Add TempControllerBase with the shared logic and three small hooks
(init_kalman, on_state_entered, post_pid) subclasses use to plug in
their own Kalman/model behavior. Each subclass now contains only what
makes it different.
Also fixes a latent crash: TempController's constructor only accepted
(dt, params), but PidFactory/brewpi.py always call it with a third
model_params arg, so pid_type "Normal" would have raised TypeError.
The shared base's model_params=None default fixes this. Also
initializes the Smith controller's trace attributes in __init__
instead of leaving them undefined until the first process() call.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>