jensandClaude Sonnet 4.6 0156e689ca config: wire TempSensor section from config.json to TempSensorSim
PlantFactory.create() now accepts sensor_config dict; extracts type and
kwargs, falls back to sigma=0.05/temp_offset=-0.15 defaults. brewpi.py
passes config.get('TempSensor', {}). Templates updated with full
TempSensor sections.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-30 19:27:04 +02:00
jensandClaude Sonnet 4.6 ca1953c9ee sensor: model real temp sensor noise in TempSensorSim
Replaces the opaque variance/√12 formula with two explicit noise components:

  sigma (default 0.05 °C) — white Gaussian noise, calibrated against the
  20260628T184903 Sud-0010 log (detrended hold-phase tick-to-tick std ≈ 0.053 °C).

  stirrer_sigma / stirrer_tau — optional AR(1) low-frequency component for
  stirrer-induced fluctuations (off by default); steady-state std equals
  stirrer_sigma, correlation time equals stirrer_tau ticks.

plant_factory.py updated to use sigma=0.05 instead of the old variance=0.01
(which gave std ≈ 0.003 °C — far too quiet).

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-30 19:17:48 +02:00
jens ead900b7b1 Build the heater/pot/sensor rig as one unit, picked by plant_name alone
heater_name/sensor_name/plant_name were three independent config keys,
each picked via its own factory - in practice sim and real hardware
are never actually mixed and matched, so this could (nonsensically)
disagree, e.g. a real heater paired with a simulated sensor.

Add PlantFactory (components/plant/plant_factory.py): plant_name alone
now builds the whole rig together. "sim" gets HeaterSim/Pot (the
modeled plant, as before)/TempSensorSim. Anything else gets
HeaterHendi/PotReal/TempSensor_max31865 - PotReal is a new, deliberately
unmodeled Pot for the real, physical kettle (components/plant/pot_real.py):
the real temperature comes straight from the real sensor, not from a
model, so it just accepts and ignores set_plant_params()/
set_ambient_temperature()/initial() and reports no temperature of its
own, satisfying PotTask/SudTask's interface with nothing to actually
simulate.

heater_name/sensor_name are gone from config.json.templ; server/brewpi.py
delegates to HeaterFactory/TempSensorFactory lazily from inside
PlantFactory, same as before, so real hardware's spidev/pyserial deps
still aren't needed just to import the module.
2026-06-23 20:22:51 +02:00