jensandClaude Sonnet 5 0171cb20c7 config: fail fast on missing TempCtrl PID gains
Config access was unchecked dict[key] everywhere, so a missing/
misnamed gain (we've hit this once already: config.json.sim's gain/
Model nesting mismatch) surfaced as a bare KeyError from deep inside
some component's __init__ or first process() tick, with no indication
which config key was wrong.

utils/config_validate.py adds a small stdlib-only dotted-path checker
(no schema library - matches this project's stdlib-first leaning) and
validate_temp_ctrl(), scoped to the section that actually caused an
incident: TempCtrl.pid_type plus every kp/ki/kd/kt gain under
TempCtrl.Outer and TempCtrl.Inner.{Heat,Hold,Cool}. Called once in
server/brewpi.py right after json.load(), before any factory runs.
Optional-with-default keys (Outer.y_hold_min, Inner.Hold.yi_max,
Thresholds) stay optional here too.

Heater/Stirrer/TempSensor/Pot sections and unknown-key warnings are
deliberately left for later - see components/pid/TODO.md.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01F4oEE99rkKVU8L8tkzXWdG
2026-07-11 12:33:57 +02:00

200 lines
12 KiB
Markdown

# components/pid design backlog
Findings from a design review, refreshed against the current state of
`master` after the Kalman-filter removal and Smith-predictor rewrite (see
git history for `temp_controller.py`/`temp_controller_smith.py`).
- [x] **FSM thresholds aren't configurable.** Moved into an optional
`TempCtrl.Thresholds` config section (`HoldIdle`, `HoldHeat`,
`IdleHeat`, `IdleHold`, `HeatHold`, `HeatIdle`), merged over
`DEFAULT_THRESHOLDS` (now in `temp_controller_base.py`, formerly
`tc_constants.py`) so existing configs without the section keep
working unchanged.
- [x] **matplotlib imported at module level in production code.**
`temp_controller.py`, `temp_controller_smith.py`, and `kalman.py`
used to `from matplotlib.pyplot import ...` just to support their
`__main__` self-test plots. The plotting demos (and `kalman_eval.py`)
moved to `scripts/demos/pid/demo_*.py`; production modules no longer
import matplotlib.
- [x] **Three Kalman filters share one tuning.** No longer applicable:
`temp_controller_smith.py` was rewritten to drop Kalman filtering
entirely (see below), so there's no shared tuning to split anymore.
- [x] **`Pid.scale()` is a gain-scheduling hack, not anti-windup.**
Fixed: removed `Pid.scale()`/`self.k` entirely. `Pid.process(err, d,
scale=1.0)` now takes the gain multiplier as a plain per-call
argument instead of mutable state, so there's nothing to go stale
across a `reset()`. `temp_controller*.py` compute `hold_scale =
1.0/heatrate_soll_set if heatrate_soll_set > 0 else 1.0` themselves
and pass it through `process_pid(theta_err, heatrate_err,
hold_scale)` — the overshoot-compensation scheduling logic now lives
entirely in the temp controller, not the generic `Pid` block.
- [ ] **No automated tests for the heat-rate filtering or Smith
correction specifically.** An earlier `tests/components/pid/` suite
(stdlib `unittest`, no pytest) covering FSM transitions, anti-windup
clamping, and Kalman convergence was removed before the Kalman-filter
removal/Smith rewrite. A new `tests/components/pid/` suite was added
alongside the HOLD-windup fix below (`test_pid.py`,
`test_temp_controller_closed_loop.py`) covering the `yi_max` clamp and
closed-loop disturbance/ramp/transition behavior, but
`_compute_heatrate()`'s backward-difference + low-pass filtering and
the two-model Smith correction itself still have no dedicated
coverage. This drives a physical heater — worth extending.
- [x] **`set_model_power` isn't defined on every controller, but
`brewpi.py` wires it unconditionally.** Fixed: `TempControllerBase`
now has a no-op `set_model_power`/`set_ambient_temperature`/
`set_model_plant_params` (`temp_controller_base.py:83-90`), so
`brewpi.py`'s unconditional `heater.set_on_changed("power_set",
tc.set_model_power)` no longer crashes for `"pid_type": "Normal"` -
`temp_controller_smith.py` still overrides `set_model_power` to
actually feed its internal model. The redundant `hasattr()` guards
at both call sites (`brewpi.py`, `components/sud_forecast.py`) were
removed along with it.
- [x] **Config access is unchecked `dict[key]` everywhere.** Partially
fixed, scoped to the section that actually caused an incident
(`config.json.sim`'s `gain`/`Model` nesting mismatch): `utils/
config_validate.py`'s `require()` is a small stdlib-only dotted-path
checker (no schema library added - matches this project's no-pytest/
stdlib-first preference), and `validate_temp_ctrl()` requires
`TempCtrl.pid_type` plus every `kp`/`ki`/`kd`/`kt` gain under
`TempCtrl.Outer` and `TempCtrl.Inner.{Heat,Hold,Cool}` - the ones every
`pid_type` reads unconditionally. Called once in `server/brewpi.py`
right after `json.load()`, before any factory runs, so a missing/
misnamed gain now fails fast with `ConfigError: missing required
config key: TempCtrl.Inner.Hold.kp` instead of a bare `KeyError` from
inside some component's `__init__` or first `process()` tick. Covered
by `tests/utils/test_config_validate.py`.
Deliberately left for later, since neither has actually crashed
anything yet: `Heater`/`Stirrer`/`TempSensor`/`Pot` config sections
(all already default gracefully via `.get(..., default)` in
`PlantFactory` etc.), and erroring (vs. just `log.warning()`) on
unknown/stale keys like the old `TempCtrl.Kalman`/`Model.kn`/
`Plant.kn`/`Model.gain` leftovers - see `components/plant/TODO.md`.
- [x] **`pid_heat` can wind up during a `HOLD`-state disturbance with no
anti-windup engagement.** A cold-water disturbance while holding drove
`pid_heat`'s integral term up without ever saturating `y` (peaked at
`y≈0.74` of the `1.0` ceiling), so the existing back-calculation
anti-windup (`Pid.process()`, `pid.py:45-48`) never triggered — the FSM
never even left `HOLD` (`diff` stayed under `HoldHeat=1.0`). The
resulting overshoot took ~35s+ to unwind naturally. A flat `yi_max`
clamp was considered and rejected: sustaining a genuine 1.5 K/min ramp
needs `y≈0.7-0.75` from `yi` alone at steady state, the same range the
disturbance itself peaked at, so no single clamp value can suppress the
windup without also capping legitimate ramps. An FSM-gating alternative
(freeze the loop's output in `HOLD` unless engaged) was also superseded.
Fixed: renamed `pid_hold`/`pid_heat`/`pid_cool` to `pid_outer`/
`pid_inner`/`pid_inner_cool` (matching what actually runs when), and
split the inner loop's config into `Inner.Heat`/`Inner.Hold`/
`Inner.Cool` so the *same* PID instance gets a tight `yi_max` only while
`HOLD` is driving it and stays unclamped for real `HEAT` ramps — no
freeze/thaw, bumpless transfer preserved for free. See
`docs/overshoot_hold_windup.md` for the full writeup, and
`docs/fsm_states.png` for a static screenshot of the FSM-states panel
of the cascade architecture diagram (states/thresholds, and the
HOLD→HEAT no-reset note). The full interactive diagram (signal-flow
cascade + FSM inset + config-mapping table) is a Claude Artifact,
not a repo file: https://claude.ai/code/artifact/a32e4752-b4a6-4153-b344-eb2423eb6512
— only reachable by whoever has access to the Claude account/session
that created it, not a durable link for the team; `docs/fsm_states.png`
is the durable copy. This was also a breaking config change (`Hold`/`Heat`/`Cool`
`Outer`/`Inner.*`) — `config.json`, the templates, and the demo scripts
were all migrated. Test coverage (closed-loop disturbance/ramp/transition
cases) was added under `tests/components/pid/` — see the "No automated
tests" item above.
- [x] **HOLD overshoot was a permanent steady-state offset, not just a
transient windup.** Found testing the rework against a real Sud run
(`sude/sud_0030.json`): a grain-fill-in disturbance during a `HOLD`
overshot by ~0.4°C (under the `HoldCool` threshold, so the FSM stayed in
`HOLD`) and then never converged back — `temp_ist` sat in a 55.3-55.4°C
band for the rest of the 20-minute hold instead of returning to 55.0.
Cause: `process_pid()`'s HOLD-state floor on `pid_outer_y` clamped to
exactly `0.0`, so once overshot, `heatrate_soll` = 0 ("hold flat") and
`pid_inner` actively fought the pot's own ambient loss to keep the
overshot temperature flat instead of declining back to setpoint. Fixed:
the floor is now a configurable `Outer.y_hold_min` (default `0.0`,
backward compatible), set to `-0.1` in `config.json`/both `.tpl`
templates, letting HOLD request a gentle decline that roughly matches
passive ambient cooling without reopening the `bb5af3c` limit cycle
(fully unclamped negative). See the "Follow-up" section in
`docs/overshoot_hold_windup.md` and
`TestHoldOvershootRecoversToSetpoint` in
`tests/components/pid/test_temp_controller_closed_loop.py`.
- [ ] **Architecture isn't ready for a real active cooler yet, only a
heat-only actuator.** Asked (not yet built): would the cascade/FSM
design still hold up if an active cooler (compressor/chiller, some
finite cooling power) replaced "heater off + passive ambient loss"?
Mostly yes at the PID/plant-model level: `Pid.y_min`/`y_max` are
already symmetric `-1.0`/`1.0` (`pid.py:12-13`), `Pot.set_power()`/
`process()` are sign-agnostic so the simulator already models negative
power correctly, and the FSM already has a dedicated `COOL` state with
its own PID instance (`pid_inner_cool`, `temp_controller_fsm.py:35-39`)
whose comment explicitly anticipates this ("the actuator ... is
responsible for clamping the resulting negative power to whatever it's
actually capable of").
The gap is at the actuator boundary: today `y` only ever reaches one
consumer, `tasks/heater.py:59`'s `self.power_actor = max(0, ... * y)`,
which silently discards every negative command — that's what's made
tuning mismatches free so far. A real cooler needs (a) a second
actuator/device class consuming the negative half instead of that
`max(0, ...)` clamp — there's no `Cooler`/chiller abstraction anywhere
yet (`grep -rniE "cooler|chiller|compressor"` across all `.py` is
empty, fully greenfield), and `heater_hendi.py:80`'s `set_power` only
clamps to a max, not a min, so feeding it a negative value today would
call `setPowerWatts(negative)` on real hardware with undefined result;
and (b) its own power ceiling, since one normalized `y` scaled by one
`get_power_max()` breaks once heater and cooler have different max
power.
Biggest risk once that clamp is removed: two separate paths start
issuing real negative-power commands that were previously harmless -
HOLD's `Outer.y_hold_min` floor (via `Inner.Hold`, see the steady-state
overshoot item above) and the pre-existing `pid_inner_cool` (via
`Inner.Cool`) - and neither has been tuned against actual active-cooling
dynamics (compressor lag, min-on-time). `Inner.Cool` in the demo
configs is literally a copy of `Inner.Heat`'s gains, never validated
independently. So adding a real cooler is a wiring task (new actuator
class, per-actuator power scaling) plus a re-tuning task (`Inner.Cool`,
and re-checking the `HoldCool`/`CoolHold` thresholds in
`temp_controller_fsm.py:14-17`), not just wiring.
- [ ] **`Outer.y_hold_min` is a fixed heuristic constant, not grounded in
the pot's actual passive-cooling capacity.** Related to the active-cooler
item above. `Pot.process()` (`components/plant/pot.py:86-89`) already
computes `p_loss = L * M * (temp - amb)` unconditionally every tick,
independent of `y` - passive cooling isn't actually *driven by* the
negative half of `y` today, it's a physics term that happens regardless
of what the controller commands. `-0.1` (see the steady-state overshoot
fix above) was picked by estimating a typical passive loss rate by hand
for one plant/ambient combination; it doesn't adapt to a different pot,
water mass, or `theta_ist - theta_amb` delta.
`TempController` (Smith, `temp_controller_smith.py:12-16,22-32`) already
carries its own internal `Pot` model with `L`/`M`/`C` and ambient
temperature set (needed for the Smith prediction) - it could expose a
`heatrate_loss_max(theta_ist) = L * (theta_ist - theta_amb) / C * 60`
(K/min) from that model and use it to size `y_hold_min` (and bound
`pid_inner_cool`'s target) dynamically per-tick, instead of a fixed
config constant - the "cooling path" would always ask for exactly what
passive loss can actually deliver, no more and no less. Also a natural
stepping stone toward the active-cooler item above: same "ceiling"
concept, just a bigger number once real cooling power exists.
Caveat: `temp_controller.py` ("Normal", non-Smith) has no internal plant
model at all - `set_model_plant_params()`/`set_ambient_temperature()`
are no-ops in `TempControllerBase` and only overridden in the Smith
subclass - so this only works for Smith out of the box; Normal would
need either its own lightweight loss estimate (e.g. from observed
`heatrate_ist` decay while power is ~0) or keep the fixed fallback.
- [ ] **`kalman.py` is now dead code in production.** Neither
`temp_controller.py` nor `temp_controller_smith.py` uses `Kalman`
anymore; the only remaining references are
`scripts/demos/pid/demo_kalman.py` and `demo_kalman_eval.py`. Decide
whether to keep it as a documented standalone filtering example or
delete it along with the demos.