Step plates now show "Ramp h:mm:ss" (ramp time only) during ramp phase
and "Hold h:mm:ss" (hold remaining) during hold phase, both in the same
digit area in green (#4ade80). Inactive steps show planned ramp duration.
Header countdown gains a "hold" row alongside the existing "ramp" (renamed
from "step") and "total" rows. All three use the same h:mm:ss format.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SH2D4LRuCnhLSzoYerAfJX
Adds HeaterTask.shutdown() which switches to open-loop at power 0,
disables TC, and broadcasts ClosedLoop=false to clients so the browser
checkbox unchecks immediately. SudTask fires it via a new set_on_end()
callback whenever state reaches DONE or IDLE, giving both a completed
schedule and a manual Stop the same safe behaviour: stirrer and heater
both off, no heater left running unattended.
Re-enabling after shutdown: check the closed-loop checkbox (sends
ClosedLoop=true → TC re-enabled) or adjust the power slider directly;
the next brew's Play press already sends ClosedLoop=true automatically.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SH2D4LRuCnhLSzoYerAfJX
Total remaining now appears above step remaining in the header. Both
countdowns and all other duration displays always use h:mm:ss format
regardless of whether hours is zero, so the layout never shifts width.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SH2D4LRuCnhLSzoYerAfJX
Steps with no 'temperature' field inherit their target from a prior step
(temperature=None in the resolved schedule). The resume-from-pause code
only called set_theta_soll when the current step had an explicit temperature,
so any manual setpoint change made during pause was never reverted for
inherited steps (e.g. sud_0010 steps 2-3 both hold at step 1's 57 °C).
Fix: save theta_soll_set at pause time; use it as fallback on resume when
the current step's temperature is None. Also set initialTempSollSync=true
in the browser on play so the slider accepts the next server Soll push
regardless of message arrival order relative to the State update.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SH2D4LRuCnhLSzoYerAfJX
- Rename "State replay on connect" to "State is server-only; GUIs only
reflect it" and expand it with the core design principle: neither GUI
client ever maintains its own model of server state — controls update
only on server push, never speculatively on user input. Multi-client
sync, stale-overwrite safety, and reconnect correctness all follow from
this single rule.
- Update TC-enable description: HeaterTask now owns the TC's enabled
switch via the closed_loop flag; SudTask no longer touches it.
- Add "Heater control modes" subsection describing Closed-loop/Open-loop,
the enable/disable rules per mode and sud state, the auto-reset on play,
and the schedule parameter restore on resume.
- Refresh the Browser client section: document the Heater control mode
checkbox, header countdown timers, and the always-reflect-server-values
slider policy; call out the server-only-state principle explicitly.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SH2D4LRuCnhLSzoYerAfJX
On resume from PAUSED, on_step_changed does not re-fire (same step
continues), so any manual TC/stirrer adjustments made while paused
would persist into the run. Explicitly re-apply the current step's
temperature, heatrate, and stirrer config on the resume path in
SudTask.recv().
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SH2D4LRuCnhLSzoYerAfJX
Closed-loop (default, checkbox checked): TC has exclusive control over
the heater; temp-soll and heatrate-soll sliders are active; direct
heater power entry is disabled. TC now stays enabled at server startup
and whenever closed-loop mode is active — SudTask no longer disables it
on IDLE/DONE, so adjusting temp-soll manually with no sud running
immediately drives the heater via the TC.
Open-loop (checkbox unchecked, only selectable when paused/stopped):
TC is disconnected from the heater; only the heater-power slider is
active. Switching back to closed-loop resets power_soll to 0 and
re-enables the TC.
On play, the mode is automatically reset to closed-loop.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SH2D4LRuCnhLSzoYerAfJX
Shows remaining time for the current step and the entire sud in large
accent-coloured monospace text to the right of the transport buttons,
matching the per-step plate colour. Hidden until a step is active.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SH2D4LRuCnhLSzoYerAfJX
Remove one-time sync guards (initialPowerSync, initialSpeedSync) so heater
power and stirrer speed sliders track the server's ist readbacks on every
push, not just on first connect. Also remove the zero-out on sud
stop/pause: with continuous ist tracking the animation and slider always
agree, and the zero-out caused them to diverge when the server kept sending
non-zero values during a pause.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SH2D4LRuCnhLSzoYerAfJX
- Remove tab system (nav#tabs, tab-btn, tab-content) from HTML/CSS/JS
- Permanent 3-column grid: manual controls (left, 16em) | LCD+pot (center) | progress (right, fills remaining)
- LCD panel stacks above pot SVG in center column, both hidden until connected
- Step plates no longer max-width capped, fill the right column
- Slider labels moved above the slider+readout row via flex-direction: column
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01DF16nV2ispNw1C9SbvqbRQ
Mirrors PyQt client which seeds doubleSpinBox_pot_temp from the
remembered ambient on startup. In the browser there is no persistence,
so the first AmbientTemp message from the server is used instead.
Flag resets on reconnect so it re-syncs if the server restarts.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01DF16nV2ispNw1C9SbvqbRQ
HeaterTask.on_changed_active() was never registered as a callback so
never fired; TcTask.recv() no longer needs to handle {Enable: ...}
since no client sends it after the override checkbox removal.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01DF16nV2ispNw1C9SbvqbRQ
During a running sud, all four manual sliders (temp soll, heat rate,
heater power, stirrer speed) are disabled for user input but update
their positions continuously from server pushes. They re-enable when
the sud stops or is paused, or on disconnect. Browser client also
resets initial-sync flags on reconnect so sliders re-sync correctly.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01DF16nV2ispNw1C9SbvqbRQ
Removing the Enabled else-if branch in a previous commit left the Soll
if-block unclosed, crashing app.js at parse time so no JS ran at all.
Also adds: onerror handler surfaces connection failures in the status
label; try/catch for invalid URL; 'Connecting…' feedback; localhost
fallback when location.hostname is empty (file:// open); wider host
input field.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01DF16nV2ispNw1C9SbvqbRQ
Drops the tc-enable, heater-activate and stirrer-activate checkboxes
and all associated state, signal connections, initial-sync flags, and
channel-handler logic. Regenerates main_window.py from the updated .ui.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01DF16nV2ispNw1C9SbvqbRQ
Replace clip-rect height manipulation with translate-scale-translate SVG
transform on fire-group, pivoting at the fixed base coordinate y=248.
Eliminates base-hopping caused by fill-box bounding-box drift from
individual flame flicker animations. Clip rect is now static (guards
against flicker overshoot above the pot bottom). Minimum visible flame
size floored at the scale corresponding to 1200W.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01JLR2133M2PyjiYq584i2G7
sudStepIndex was reset to null in updateSudForecast whenever
isNewSchedule=true (i.e. on every fresh page load). If the Step
message arrived before Json in the global-state replay, or in a
separate message, the schedule would be rebuilt but the index
would be null, leaving grain mass as 0 with no subsequent Step
to restore it.
Step messages are the authoritative source for the current index,
so the reset is removed. The Step handler always overwrites it.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01JLR2133M2PyjiYq584i2G7
Water fill height now reflects water_mass + grain_mass*0.7 (grain
displacement). A small blue tick and label on the left pot wall shows
the utilized volume in litres, hidden when the pot is unconfigured.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01JLR2133M2PyjiYq584i2G7
- Stirrer starts at speed 0 (was 50) so blades don't spin on connect
- Grain particles only levitate when stirrer is running
- Fire size driven by PowerSet (soll) instead of Power (ist)
- Split animation-play-state out of stirrer shorthand for reliable pausing
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01JLR2133M2PyjiYq584i2G7
Replace scaleY group transform with a dynamic clipPath that reveals
flame height proportional to heater power. Base at y=256 stays fixed;
only the tips grow with intensity. Includes flicker overshoot buffer.
Fire paths shifted +8px down, viewBox extended to 265.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01DGKe8JzTM2Gr1fdx9wYXTi
35 particles distributed across full pot height, clipped to dynamic
water area via water-clip-rect updated alongside water fill level.
Particle opacity transitions on grain_mass changes per step.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01DGKe8JzTM2Gr1fdx9wYXTi
- SVG fire group with 3 layered flame paths (red/orange/yellow gradients)
- CSS keyframe flicker animations with different timings per flame layer
- JS controls fire opacity and scaleY proportional to heater power
- Fix buildStep() reading grain_mass/water_mass from nested step.pot
instead of flat step keys, matching the JSON structure
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01DGKe8JzTM2Gr1fdx9wYXTi
- Add volumen field to all sud JSON pot entries (30 L)
- Fix parseSudDoc to read from nested doc.pot (was using stale flat keys)
- SVG widget shows transparent rectangular pot with stirrer, thermometer
with live temperature, and water fill level (water_mass/volumen) when
a sud is loaded; no water shown when no sud is loaded
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01DGKe8JzTM2Gr1fdx9wYXTi
Update set_step(), status bar mass display, and on_action_sud_new() to
read grain_mass/water_mass from step['pot'] and use the new pot key
structure when sending an empty Load document.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01T52JH848ojhXXHn1bAzdC3
In estimate()'s on_step_changed closure, the new 'pot = step.get("pot", {})'
local variable shadowed the outer 'pot' (Pot plant instance), causing
pot.set_plant_params() to be called on a plain dict and crash on load.
Renamed to 'step_pot' to avoid the collision.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01T52JH848ojhXXHn1bAzdC3
Top-level pot_mass/pot_material/L/Td/grain_mass/water_mass and their
per-step overrides are now grouped under a 'pot' sub-object, matching
the structure already applied to sud_0010.json's parent level. Updated
all sude/*.json files and the parsing/consuming code in components/sud.py,
tasks/sud.py, components/sud_forecast.py, and scripts/demos/sud/demo_sud.py.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01T52JH848ojhXXHn1bAzdC3
- Browser: OK button sends Confirm without closing dialog; Escape blocked;
dialog closes when state leaves WAIT_USER (server-driven).
- PyQt: non-blocking QDialog replaces blocking QMessageBox; OK sends Confirm
without closing; dialog closed by server state change or on disconnect.
- ws_client.py: remove deprecated loop= params from websockets.connect() and
asyncio.ensure_future() (same fix already applied to ws_server.py) so the
PyQt client can actually connect with websockets >= 10.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Tqxrk8uj4M3w3d3eXm3xK8
With TempControllerBase(APid, TempControllerFsm), APid.is_holding()
(abstract stub returning None) shadowed TempControllerFsm.is_holding()
in the MRO, so tc.is_holding() always returned None. The forecast
simulation never called sud.temp_reached() and always hit MAX_TICKS.
Swapping to TempControllerBase(TempControllerFsm, APid) puts the
concrete FSM methods before APid's abstract stubs in the MRO.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Tqxrk8uj4M3w3d3eXm3xK8
States, DEFAULT_THRESHOLDS, the three PIDs, FSM state vars, process_fsm(),
on_state_entered(), set_enabled(), and is_holding() move to a new
TempControllerFsm class in temp_controller_fsm.py. TempControllerBase
inherits from both APid and TempControllerFsm; States is re-exported so
existing imports in temp_controller_smith.py are unaffected.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Tqxrk8uj4M3w3d3eXm3xK8
All four name-dispatch factories repeated the same if/elif lazy-import
pattern. Replace with a ComponentFactory base class holding a callable
registry and a _lazy() helper for the common import-and-construct case.
PlantFactory is an orchestrator, not a dispatcher, and is left as-is.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Tqxrk8uj4M3w3d3eXm3xK8
Callbacks were registered inside the async on_process() coroutine,
meaning they weren't active until the event loop started ticking.
Moving them to __init__ ensures they're wired up at construction time.
Also removes remaining debug prints from the affected task files.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Tqxrk8uj4M3w3d3eXm3xK8