jens
|
5865923854
|
- refactored params
|
2020-12-21 12:24:42 +01:00 |
|
jens
|
262f1ef663
|
- refactored params
|
2020-12-21 12:24:31 +01:00 |
|
jens
|
6649a03d44
|
- PID: no params for constructor
- adedd dt
- fixed set_params
|
2020-12-21 12:23:56 +01:00 |
|
jens
|
b9b1a1c613
|
- PID: added set_param()
|
2020-12-21 11:28:44 +01:00 |
|
jens
|
5f60312d4e
|
- Pid: D-Part need not to be error based
- increased pot delay to 30 s
|
2020-12-20 18:23:14 +01:00 |
|
jens
|
24437329f0
|
- Compensate for max heat rate to reduce overshoot
|
2020-12-16 19:54:38 +01:00 |
|
jens
|
71cd87085f
|
- load params from config.json
|
2020-12-16 18:42:05 +01:00 |
|
jens
|
6dd0920010
|
- refactored
|
2020-12-16 17:13:57 +01:00 |
|
jens
|
fa93a3911e
|
- refactored
|
2020-12-16 17:10:46 +01:00 |
|
jens
|
73d1c844b0
|
- improved Kalman eval
|
2020-12-16 09:07:52 +01:00 |
|
jens
|
2327b214fc
|
- increased kp
|
2020-12-13 16:31:20 +01:00 |
|
jens
|
0633e464ca
|
- refactored
- created TempSensorFactory
|
2020-12-13 16:21:08 +01:00 |
|
jens
|
c401885967
|
- added
|
2020-12-13 15:53:46 +01:00 |
|
jens
|
752bb18ef5
|
- refactored
|
2020-12-13 14:52:16 +01:00 |
|
jens
|
e26b4bfba0
|
- refactored
|
2020-12-13 14:47:42 +01:00 |
|
jens
|
8ec7dfbc98
|
- refactored
|
2020-12-13 14:23:26 +01:00 |
|
jens
|
8d57299d83
|
-added anti windup
|
2020-12-11 15:17:52 +01:00 |
|
jens
|
e5139c5695
|
- PID-T doesn't need integral term
|
2020-12-11 14:23:43 +01:00 |
|
jens
|
ada81935e3
|
- temp controller: use series PID for T and dT. PID-T sets setpoint on PIT-dT
|
2020-12-11 12:43:12 +01:00 |
|
jens
|
52e3cf733d
|
- TC: use offset
|
2020-12-10 12:46:13 +01:00 |
|
jens
|
424f1d0d0f
|
- fixed initial value for temp_controller
|
2020-12-10 09:40:38 +01:00 |
|
jens
|
a80cc2bf01
|
- TC: prepared for Rate set and get
- improved TC state machine
|
2020-12-06 12:05:55 +01:00 |
|
jens
|
493af820dc
|
- TC: state IDLE introduced
- TC: send states
|
2020-12-06 11:34:54 +01:00 |
|
jens
|
448afb3e9a
|
- refactored PID params
|
2020-12-05 18:40:23 +01:00 |
|
jens
|
55aa043efb
|
- tempcontroller: added heat rate control
|
2020-12-05 18:33:16 +01:00 |
|
jens
|
6a6ca8c92d
|
- PID: reverted yi reset on sign(err) change
|
2020-12-02 11:30:28 +01:00 |
|
jens
|
6939650708
|
- PID: use pot for testing
|
2020-12-02 11:24:31 +01:00 |
|
jens
|
d6037b33d3
|
- PID: Modified AWU code
|
2020-12-01 23:21:45 +01:00 |
|
jens
|
5260af8bbd
|
- PID: Reset yi on error sign changes
|
2020-12-01 21:59:03 +01:00 |
|
jens
|
8b481a98b8
|
- removed dbug prints
- PID: added Anti Windup code
|
2020-12-01 21:17:30 +01:00 |
|
jens
|
5102ad935c
|
- fixed water model
|
2020-11-29 19:12:17 +01:00 |
|
jens
|
d9c587476f
|
- added Temp controller
- use AttributeChange for Processing objects
|
2020-11-29 14:35:44 +01:00 |
|
jens
|
9d609df44f
|
- improved Kalman test
|
2020-11-27 19:43:41 +01:00 |
|
jens
|
63e4115db8
|
- improved temp controller test
|
2020-11-27 12:04:45 +01:00 |
|
jens
|
db464080d9
|
- improved temp controller test
|
2020-11-26 22:04:22 +01:00 |
|
jens
|
18103df836
|
- fixed Kalman
|
2020-11-26 20:41:42 +01:00 |
|
jens
|
e867bd574e
|
- fixed Kalman
|
2020-11-26 20:33:56 +01:00 |
|
jens
|
bf205742b1
|
- added Pid
- added Temp Controller
- added Kalman
|
2020-11-26 19:57:28 +01:00 |
|
jens
|
636070fd61
|
initial import
|
2020-11-24 18:34:47 +01:00 |
|