Heater and Stirrer can be real serial hardware (hendi, Pololu1376), but
there was no connection concept at all - the constructors opened the
port and crashed the whole server if the device was missing, with no
way to see connection status or firmware version and no way to
reconnect without a restart.
Adds an observable Connectable mixin (components/connectable.py) shared
by AHeater/AStirrer; real devices defer opening the serial port to an
explicit connect(), auto-connect on server startup, and surface
Connected/FirmwareVersion/Simulated plus manual Connect/Disconnect over
the web GUI. Heating/stirring and Sud Start are all gated on connection
state, and a disconnect mid-brew force-stops the run via the same path
as a manual Stop.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YaPLuRPpyjWcwhMvCvpHCL
HeaterTask.shutdown() switched the heater to open-loop when a brew
ended, but nothing switched it back when a new Sud was started. The
browser happened to send {ClosedLoop: true} as part of its UI setup,
so its connect-and-start path worked; PyQt (and any other client that
doesn't send that message) left the heater in open-loop and the TC
never drove it.
Add SudTask._on_start / set_on_start() hook, HeaterTask.start_closed_loop()
(mirror of shutdown()), and wire them in brewpi.py so the server
switches to closed-loop and broadcasts the new state to all clients the
moment any client starts a brew.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Adds HeaterTask.shutdown() which switches to open-loop at power 0,
disables TC, and broadcasts ClosedLoop=false to clients so the browser
checkbox unchecks immediately. SudTask fires it via a new set_on_end()
callback whenever state reaches DONE or IDLE, giving both a completed
schedule and a manual Stop the same safe behaviour: stirrer and heater
both off, no heater left running unattended.
Re-enabling after shutdown: check the closed-loop checkbox (sends
ClosedLoop=true → TC re-enabled) or adjust the power slider directly;
the next brew's Play press already sends ClosedLoop=true automatically.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SH2D4LRuCnhLSzoYerAfJX
Closed-loop (default, checkbox checked): TC has exclusive control over
the heater; temp-soll and heatrate-soll sliders are active; direct
heater power entry is disabled. TC now stays enabled at server startup
and whenever closed-loop mode is active — SudTask no longer disables it
on IDLE/DONE, so adjusting temp-soll manually with no sud running
immediately drives the heater via the TC.
Open-loop (checkbox unchecked, only selectable when paused/stopped):
TC is disconnected from the heater; only the heater-power slider is
active. Switching back to closed-loop resets power_soll to 0 and
re-enables the TC.
On play, the mode is automatically reset to closed-loop.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SH2D4LRuCnhLSzoYerAfJX
HeaterTask.on_changed_active() was never registered as a callback so
never fired; TcTask.recv() no longer needs to handle {Enable: ...}
since no client sends it after the override checkbox removal.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01DF16nV2ispNw1C9SbvqbRQ
Callbacks were registered inside the async on_process() coroutine,
meaning they weren't active until the event loop started ticking.
Moving them to __init__ ensures they're wired up at construction time.
Also removes remaining debug prints from the affected task files.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Tqxrk8uj4M3w3d3eXm3xK8
Embeds a dark-themed matplotlib canvas (3 stacked strip charts: theta
ist/soll, heatrate ist/soll, heater power_set/power_eff) in a new Plot
tab, sampled once per second from the latest websocket-received values.
HeaterTask now also emits a PowerSet message (the pre-discretization
target power) alongside the existing Power (effective) message, since
the GUI had no way to see the set-point side of figure 1's bottom plot
otherwise.