Files
brewpi/tasks/heater.py
T
jensandClaude Sonnet 5 f20e617d81 feat: add connect/disconnect status for real heater/stirrer hardware
Heater and Stirrer can be real serial hardware (hendi, Pololu1376), but
there was no connection concept at all - the constructors opened the
port and crashed the whole server if the device was missing, with no
way to see connection status or firmware version and no way to
reconnect without a restart.

Adds an observable Connectable mixin (components/connectable.py) shared
by AHeater/AStirrer; real devices defer opening the serial port to an
explicit connect(), auto-connect on server startup, and surface
Connected/FirmwareVersion/Simulated plus manual Connect/Disconnect over
the web GUI. Heating/stirring and Sud Start are all gated on connection
state, and a disconnect mid-brew force-stops the run via the same path
as a manual Stop.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YaPLuRPpyjWcwhMvCvpHCL
2026-07-03 19:18:59 +02:00

163 lines
5.5 KiB
Python
Executable File

import asyncio
from tasks import ATask
from components import AHeater
from ws.message import MsgIo
from utils.value import ChangedInteger
class HeaterTask(ATask):
def __init__(self, device: AHeater, interval, msg_handler: MsgIo):
ATask.__init__(self, interval)
self.device = device
self.interval = interval
self.msg_handler = msg_handler
msg_handler.set_recv_handler(self.recv)
self.power_soll = 0
self.power_actor = 0
self.closed_loop = True
self._on_closed_loop_changed = None
self.pulse_counter = 0
self._on_connected_changed = None
device.set_on_changed('power_eff', ChangedInteger(self.on_changed_power).set)
device.set_on_changed('connected', self.on_connected_changed)
device.set_on_changed('firmware_version', self.on_firmware_version_changed)
self.power_set_changed = ChangedInteger(self.on_changed_power_set).set
def set_on_closed_loop_changed(self, callback):
self._on_closed_loop_changed = callback
def set_on_connected_changed(self, callback):
"""Registers a callback(connected: bool) invoked whenever the
device's connection state changes - lets server/brewpi.py wire this
into SudTask's start-gating/mid-brew auto-stop."""
self._on_connected_changed = callback
def on_connected_changed(self, value):
asyncio.create_task(self.send({'Connected': value}))
if self._on_connected_changed:
self._on_connected_changed(value)
def on_firmware_version_changed(self, value):
asyncio.create_task(self.send({'FirmwareVersion': value}))
def shutdown(self):
"""Called when the brew ends (DONE/IDLE). Switches to open-loop at
power 0 and disables TC, mirroring what a Stop press should do."""
self.closed_loop = False
self.power_soll = 0
if self._on_closed_loop_changed:
self._on_closed_loop_changed(False)
asyncio.create_task(self.send({'ClosedLoop': False}))
self.power_set_changed(0)
def start_closed_loop(self):
"""Called when a Sud starts. Re-enables closed-loop so the TC drives
the heater regardless of which client started the brew."""
self.closed_loop = True
if self._on_closed_loop_changed:
self._on_closed_loop_changed(True)
asyncio.create_task(self.send({'ClosedLoop': True}))
def actor(self, y):
self.power_actor = max(0, self.device.get_power_max() * y)
def on_changed_power(self, power):
asyncio.create_task(self.send({'Power': power}))
def on_changed_power_set(self, power):
asyncio.create_task(self.send({'PowerSet': power}))
async def recv(self, data):
for pair in data.items():
if pair[0] == 'ClosedLoop':
self.closed_loop = pair[1]
if self.closed_loop:
self.power_soll = 0
if self._on_closed_loop_changed:
self._on_closed_loop_changed(self.closed_loop)
await self.send({'ClosedLoop': self.closed_loop})
elif pair[0] == 'Connect':
if self.device.connect():
self.device.activate(True)
elif pair[0] == 'Disconnect':
self.device.activate(False)
self.device.disconnect()
elif 'Power' in pair[0]:
self.power_soll = pair[1]
async def send(self, data):
await self.msg_handler.send(data)
def get_next_smaller_power(self, power):
result = self.device.get_power_min()
p_list = [p for p in self.device.get_powers() if p <= power]
if len(p_list) > 0:
result = p_list[-1]
return result
def get_next_greater_power(self, power):
result = self.device.get_power_min()
p_list = [p for p in self.device.get_powers() if p > power]
if len(p_list) > 0:
result = p_list[0]
return result
async def on_process(self):
await self.send({'Capabilities': {'Power': {'Min': 0, 'Max': self.device.get_power_max()}}})
await self.send({'Simulated': self.device.simulated})
await self.send({'ClosedLoop': self.closed_loop})
if self._on_closed_loop_changed:
self._on_closed_loop_changed(self.closed_loop)
pulse_period_s = 10
pulse_period_count = pulse_period_s/self.interval
# Auto-connect on startup - replaces what used to happen implicitly
# in the device's own constructor; a missing/unplugged device just
# stays disconnected instead of crashing the server (see
# components/actor/heater_hendi.py's connect()).
self.device.connect()
# Explicit initial push, same as Capabilities/Simulated/ClosedLoop
# above - a simulated device's connect() is a no-op that never
# reassigns self.connected (see components/connectable.py), so its
# set_on_changed('connected', ...) observer would otherwise never
# fire and a freshly-subscribed client would never learn it's
# connected.
await self.send({'Connected': self.device.connected})
await self.send({'FirmwareVersion': self.device.firmware_version})
with self.device.open():
while True:
# Closed-loop: TC has full control. Open-loop: direct manual power only.
power_soll = self.power_actor if self.closed_loop else self.power_soll
self.power_set_changed(power_soll)
# Calculate duty cycle
power_low = self.get_next_smaller_power(power_soll)
power_high = self.get_next_greater_power(power_soll)
power_step = power_high - power_low
power_diff = power_soll - power_low
duty = power_diff / power_step
on_count = pulse_period_count*duty
self.pulse_counter += 1
if self.pulse_counter >= pulse_period_count:
self.pulse_counter = 0
if power_soll == 0 or self.pulse_counter >= on_count:
self.device.set_power(power_low)
elif self.pulse_counter < on_count:
self.device.set_power(power_high)
try:
self.device.process()
except Exception as e:
print(f"HeaterTask: comm error, marking disconnected: {e}")
self.device.disconnect()
await asyncio.sleep(self.interval)