Confirmed on hardware: 15s idle while remote-enabled with the heater
on and powered auto-suspends (R? and S? both drop to 0). P? does not
read literal 0 though - it lands on 4095, the raw register's max value
past the calibrated curve's low end, not the digit 0. Any check
expecting P?=="0" to confirm zero power would be wrong on this
firmware; S? is the correct check.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01GpePKZiEZWbGo9HrfuML6U
HendiCtrl.cmd() previously raised a bare "Communication error" for any
non-OK response, discarding the firmware's actual reply. It now
includes the raw echo/answer bytes, and --debug prints every
request/response. Using this, the rejected R1 during lockout turned
out to be an explicit "ERR:Invalid state" reply, not a timeout.
Also flashed and retested v1.16: plain reconnect (no --reset) now
recovers from the lockout reliably (4/4 trials), fixing the
intermittent behavior seen on v1.15.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01GpePKZiEZWbGo9HrfuML6U
--reset still reliably clears the lockout on v1.15, same as v1.14. A
plain reconnect without --reset now succeeds intermittently (1 of 3
trials) where it always failed before, but that's unreliable enough to
flag as a remaining race condition rather than a fix.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01GpePKZiEZWbGo9HrfuML6U
Firmware v1.14 makes --reset (DTR/RTS toggle) reliably clear the
ungraceful-disconnect lockout, unlike v1.12. A plain reconnect without
--reset still fails on both versions, so recovery is specifically tied
to the reset line, not just a fresh connection.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01GpePKZiEZWbGo9HrfuML6U