16 Commits
Author SHA1 Message Date
jens a1864a5257 log: route task/component status output through logging, not print()
AttributeChange (the common base of every ATask and component ABC) now
sets self.log = logging.getLogger(type(self).__name__), so components
no longer need to hand-type their own name into each message. Wired
logging.basicConfig() in server/brewpi.py with a bare "%(name)s:
%(message)s" formatter - Tee (see prior commit) still supplies the
"<date>T<time>:" prefix, so lines read "<date>T<time>:<component>:
<message>" without double-stamping, and third-party loggers
(websockets, asyncio) now get the same formatting for free.

Converted the print() call sites that were standing in for this in
tasks/ and components/ (leaving __main__ demo blocks and explicit
debug-dump helpers alone).
2026-07-10 22:00:04 +02:00
jensandClaude Sonnet 5 671e0c2474 fix: heater task permanently died after a mid-brew unplug, never recovered
Root cause (from the brewpi Pi's log): HendiCtrl.disconnect() only
caught HendiException (a protocol-level NAK), but a genuine unplug
fails deep inside pyserial itself - flushInput()/readline() raise
termios.error/OSError on the now-dead fd. That escaped disconnect()
uncaught (skipping self.ser.close() too), then kept propagating up
through every caller that invoked disconnect() from its own except
handler (HeaterHendi.process()/activate(), AHeater.open()'s
context-manager exit), all the way out of HeaterTask.on_process()'s
coroutine entirely. Nothing restarts a dead ATask, so the heater's
process()/duty-cycle loop was gone for the rest of the process's
life - reconnecting afterward changed `connected` back to True but
nothing was left running to ever call process() again.

Fixes:
- HendiCtrl.disconnect() now catches broadly and always closes the
  port, matching Pololu1376.disconnect()'s already-correct pattern.
- HeaterTask/StirrerTask.on_process() gain an outer retry loop as a
  safety net: even an unanticipated exception now logs, marks
  disconnected, and re-enters rather than permanently killing the
  task.

Verified by reproducing the exact failure (comm error raising a raw
OSError, not HendiException) against a fake device - the task now
survives and resumes process()ing once reconnected.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YaPLuRPpyjWcwhMvCvpHCL
2026-07-03 21:21:44 +02:00
jensandClaude Sonnet 5 f20e617d81 feat: add connect/disconnect status for real heater/stirrer hardware
Heater and Stirrer can be real serial hardware (hendi, Pololu1376), but
there was no connection concept at all - the constructors opened the
port and crashed the whole server if the device was missing, with no
way to see connection status or firmware version and no way to
reconnect without a restart.

Adds an observable Connectable mixin (components/connectable.py) shared
by AHeater/AStirrer; real devices defer opening the serial port to an
explicit connect(), auto-connect on server startup, and surface
Connected/FirmwareVersion/Simulated plus manual Connect/Disconnect over
the web GUI. Heating/stirring and Sud Start are all gated on connection
state, and a disconnect mid-brew force-stops the run via the same path
as a manual Stop.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YaPLuRPpyjWcwhMvCvpHCL
2026-07-03 19:18:59 +02:00
jensandClaude Sonnet 5 5bc278e875 feat: add --debug tracing to hendi_ctrl_app.py, document v1.16 fix
HendiCtrl.cmd() previously raised a bare "Communication error" for any
non-OK response, discarding the firmware's actual reply. It now
includes the raw echo/answer bytes, and --debug prints every
request/response. Using this, the rejected R1 during lockout turned
out to be an explicit "ERR:Invalid state" reply, not a timeout.

Also flashed and retested v1.16: plain reconnect (no --reset) now
recovers from the lockout reliably (4/4 trials), fixing the
intermittent behavior seen on v1.15.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01GpePKZiEZWbGo9HrfuML6U
2026-07-02 18:44:00 +02:00
jensandClaude Sonnet 5 5522b9c491 refactor: move hendiCtrl.py's main() into scripts/hendi_ctrl_app.py
hendiCtrl.py is now import-only. The new CLI app exposes serial
port/baudrate, version/capability info, converter test, heater test,
and firmware update as separate flags, instead of one fixed script.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01GpePKZiEZWbGo9HrfuML6U
2026-07-02 17:02:21 +02:00
jens 1bcabb0ccc added firmware info to hendi and motor driver 2026-07-02 16:33:37 +02:00
jens 801e9809a6 hendiCtrl: fixed graceful close 2026-06-30 18:59:33 +02:00
jensandClaude Sonnet 4.6 5751d26873 server: graceful Ctrl-C shutdown; HendiCtrl closes connection cleanly
On KeyboardInterrupt, brewpi.py cancels all asyncio tasks (letting
HeaterTask's `with device.open()` finally block run), then calls
heater.close() as belt-and-suspenders before closing the event loop.

On shutdown HeaterHendi.activate(False) now sets the switch to 0 instead
of disabling remote control, so the Hendi stays in remote mode at 0 W
rather than dropping back to its local panel state.  HendiCtrl.close()
does the same (setSwitch(0)) then closes the serial port.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-30 18:26:54 +02:00
jens 29dd5267a9 - fixed hendiCtrl exceptions 2026-06-30 17:05:43 +02:00
jens 8ca4e4d803 fixed duplicate class declaration 2026-06-30 16:38:51 +02:00
jens 6547478d00 HendiCtrl: better Exceptions 2026-06-30 16:22:06 +02:00
jens bd63f2648c - refactored hendi_ctrl
- fixed hend_heater
- added workaround for typedDict and Python < v3.8
2021-10-19 06:32:45 +01:00
jens 9b997b8348 - generalized heaters 2021-10-18 14:32:56 +02:00
jens 9ddcd547d1 - fixed args 2020-12-17 17:33:38 +01:00
jens 5f1a8a94e0 - hendi: added open() with context manager
- heaterSim: use 100 Watt steps
2020-12-17 14:08:05 +01:00
jens 48d0baa74f - added 2020-12-16 16:55:02 +01:00