Files
brewpi/tasks/heater.py
T
jensandClaude Sonnet 5 7b162cf1f5 refactor: drop firmware-version display, move Enable toggle to Controller
Firmware version is already printed to the log at connect() time
(HendiCtrl/Pololu1376) - remove the live GUI/websocket firmware
reporting entirely (Connectable, HeaterHendi/StirrerPololu1376,
Heater/StirrerTask, web GUI) as redundant.

Also move the Heater panel's Closed-loop checkbox into the Controller
panel and rename it "Enable" - the Controller panel now shows a
live Enabled (green) / Disabled (gray) status badge next to its
heading, matching the Connected/Disconnected badges on the Heater/
Stirrer panels.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YaPLuRPpyjWcwhMvCvpHCL
2026-07-03 20:23:55 +02:00

158 lines
5.3 KiB
Python
Executable File

import asyncio
from tasks import ATask, fire_and_forget
from components import AHeater
from ws.message import MsgIo
from utils.value import ChangedInteger
class HeaterTask(ATask):
def __init__(self, device: AHeater, interval, msg_handler: MsgIo):
ATask.__init__(self, interval)
self.device = device
self.interval = interval
self.msg_handler = msg_handler
msg_handler.set_recv_handler(self.recv)
self.power_soll = 0
self.power_actor = 0
self.closed_loop = True
self._on_closed_loop_changed = None
self.pulse_counter = 0
self._on_connected_changed = None
device.set_on_changed('power_eff', ChangedInteger(self.on_changed_power).set)
device.set_on_changed('connected', self.on_connected_changed)
self.power_set_changed = ChangedInteger(self.on_changed_power_set).set
def set_on_closed_loop_changed(self, callback):
self._on_closed_loop_changed = callback
def set_on_connected_changed(self, callback):
"""Registers a callback(connected: bool) invoked whenever the
device's connection state changes - lets server/brewpi.py wire this
into SudTask's start-gating/mid-brew auto-stop."""
self._on_connected_changed = callback
def on_connected_changed(self, value):
fire_and_forget(self.send({'Connected': value}))
if self._on_connected_changed:
self._on_connected_changed(value)
def shutdown(self):
"""Called when the brew ends (DONE/IDLE). Switches to open-loop at
power 0 and disables TC, mirroring what a Stop press should do."""
self.closed_loop = False
self.power_soll = 0
if self._on_closed_loop_changed:
self._on_closed_loop_changed(False)
asyncio.create_task(self.send({'ClosedLoop': False}))
self.power_set_changed(0)
def start_closed_loop(self):
"""Called when a Sud starts. Re-enables closed-loop so the TC drives
the heater regardless of which client started the brew."""
self.closed_loop = True
if self._on_closed_loop_changed:
self._on_closed_loop_changed(True)
asyncio.create_task(self.send({'ClosedLoop': True}))
def actor(self, y):
self.power_actor = max(0, self.device.get_power_max() * y)
def on_changed_power(self, power):
asyncio.create_task(self.send({'Power': power}))
def on_changed_power_set(self, power):
asyncio.create_task(self.send({'PowerSet': power}))
async def recv(self, data):
for pair in data.items():
if pair[0] == 'ClosedLoop':
self.closed_loop = pair[1]
if self.closed_loop:
self.power_soll = 0
if self._on_closed_loop_changed:
self._on_closed_loop_changed(self.closed_loop)
await self.send({'ClosedLoop': self.closed_loop})
elif pair[0] == 'Connect':
if self.device.connect():
self.device.activate(True)
elif pair[0] == 'Disconnect':
self.device.activate(False)
self.device.disconnect()
elif 'Power' in pair[0]:
self.power_soll = pair[1]
async def send(self, data):
await self.msg_handler.send(data)
def get_next_smaller_power(self, power):
result = self.device.get_power_min()
p_list = [p for p in self.device.get_powers() if p <= power]
if len(p_list) > 0:
result = p_list[-1]
return result
def get_next_greater_power(self, power):
result = self.device.get_power_min()
p_list = [p for p in self.device.get_powers() if p > power]
if len(p_list) > 0:
result = p_list[0]
return result
async def on_process(self):
await self.send({'Capabilities': {'Power': {'Min': 0, 'Max': self.device.get_power_max()}}})
await self.send({'Simulated': self.device.simulated})
await self.send({'ClosedLoop': self.closed_loop})
if self._on_closed_loop_changed:
self._on_closed_loop_changed(self.closed_loop)
pulse_period_s = 10
pulse_period_count = pulse_period_s/self.interval
# Auto-connect on startup - replaces what used to happen implicitly
# in the device's own constructor; a missing/unplugged device just
# stays disconnected instead of crashing the server (see
# components/actor/heater_hendi.py's connect()).
self.device.connect()
# Explicit initial push, same as Capabilities/Simulated/ClosedLoop
# above - a simulated device's connect() is a no-op that never
# reassigns self.connected (see components/connectable.py), so its
# set_on_changed('connected', ...) observer would otherwise never
# fire and a freshly-subscribed client would never learn it's
# connected.
await self.send({'Connected': self.device.connected})
with self.device.open():
while True:
# Closed-loop: TC has full control. Open-loop: direct manual power only.
power_soll = self.power_actor if self.closed_loop else self.power_soll
self.power_set_changed(power_soll)
# Calculate duty cycle
power_low = self.get_next_smaller_power(power_soll)
power_high = self.get_next_greater_power(power_soll)
power_step = power_high - power_low
power_diff = power_soll - power_low
duty = power_diff / power_step
on_count = pulse_period_count*duty
self.pulse_counter += 1
if self.pulse_counter >= pulse_period_count:
self.pulse_counter = 0
if power_soll == 0 or self.pulse_counter >= on_count:
self.device.set_power(power_low)
elif self.pulse_counter < on_count:
self.device.set_power(power_high)
try:
self.device.process()
except Exception as e:
print(f"HeaterTask: comm error, marking disconnected: {e}")
self.device.disconnect()
await asyncio.sleep(self.interval)