# components/plant design backlog Findings from reviewing `pot.py`'s water-bath model against real-plant behavior (sim/real control mismatch reported by user). Not yet acted on. - [ ] **Heat-loss term has wrong units.** `pot.py:37`: `leak = 1/self.M * self.L * (self.theta_amb - self.temp)/self.theta_amb`. The power term right above it is `power/(self.M * self.C)` (W / (J/K) -> K/s). `leak` should follow the same pattern — `self.L * (self.theta_amb - self.temp) / (self.M * self.C)` — but instead it's missing `/C` and divides by `theta_amb` (~20) instead, which isn't a physically meaningful normalization. With `C=4190` this suppresses ambient heat loss by ~3-4 orders of magnitude versus what the power term implies, so the simulated pot barely cools at all. The Smith predictor's internal model is also a `Pot` instance with the identical bug, so this never showed up in sim-vs-sim testing — only against the real plant. Likely the primary cause of the sim/real control mismatch. - [ ] **`kn` is loaded but never applied.** `pot.py:18` reads `params['kn']` but nothing in `process()`/`get_temperature()` uses it. Git history shows it used to add Gaussian sensor noise (`self.kn * np.random.normal(...)`) to the output, since commented out and then dropped during the heat-diffusion refactor. Sim is currently fully deterministic/noise-free, making the Kalman filter and PID derivative term look better-behaved in sim than they will against a real noisy sensor. Re-enable as measurement noise (and decide if process noise is also wanted). - [ ] **`theta_amb` is hardcoded, not configured.** `brewpi.py:40` passes a literal `20` instead of reading it from config or a live ambient sensor. Real ambient temperature drifts and is never modeled as a disturbance, so the controller's robustness to it is untested. - [ ] **Thermal lag modeled as single-pole lag, not transport delay.** `HeatDiffusion` (`heat_diffusion.py`) implements `alpha=dt/Td` exponential smoothing, not true dead time. There's already a `Delay` class (`plant/delay.py`) for pure transport delay, dropped in favor of `HeatDiffusion` in commit `16cb3d3`. If the real pot's heater-to-sensor coupling behaves more like dead time (heat must propagate through the water before reaching the sensor) than a single lag, `Td` won't represent the same dynamic in sim vs. reality, and the Smith predictor's delay compensation (which assumes `Td` matches the real plant) will be off. - [ ] **No actuator/process realism.** No heater power saturation enforced inside `Pot` itself (handled ad hoc in test harnesses), no evaporation/lid heat loss, no varying thermal mass `M` as volume changes (e.g. boil-off, adding water/grain) — `M` is a fixed constant for the whole simulation.