# Hendi remote-control lockout findings Firmware under test: **v1.12** (`getSoftwareVersion()` / `I?`+`V?` via `components/actor/hendiCtrl.py`). Reproduced and verified on real hardware using `scripts/hendi_ctrl_app.py`'s `--trigger-error-state`, `--reset` and `--test-heater` flags. ## Trigger Calling `remoteEnable(True)` (`R1`) and then disconnecting/exiting without a matching `remoteEnable(False)` (`R0`) - i.e. an ungraceful disconnect while remote control is enabled - puts the device into a locked-out state. ## Recovery attempts | # | Recovery method | Mechanism | Result | |---|---|---|---| | 1 | `--reset` (toggle DTR/RTS reset line) | Soft reset via serial control lines, no power loss | **Fails** - `remoteEnable(True)` still returns `HendiException("Communication error")` on the next connection | | 2 | `--reset` immediately followed by `--test-heater` in the *same* process/connection | Soft reset, then reuse the still-open serial connection | Succeeded once, but not reproducible across repeat isolated attempts - not a reliable recovery path | | 3 | Physical power cycle (device knob) | Full power-off/on of the unit | **Recovers** - `remoteEnable(True)` succeeds immediately afterward, heater sweep runs cleanly | ## Symptom while locked out - `I?` / `V?` (software identifier/version queries) still respond normally. - `R1` (`remoteEnable(True)`) fails with a communication error - this is the only observed symptom, and it blocks any command path that needs remote control enabled (e.g. `--test-heater`). ## Conclusion On firmware v1.12, only a physical power cycle clears the lockout; neither a serial soft-reset nor a fresh serial reconnect does. This is the behavior the planned firmware fix should address - a graceful-disconnect timeout, an explicit unlock command, or making the DTR/RTS reset line actually clear the lockout flag.