# components/pid design backlog Findings from a design review, refreshed against the current state of `master` after the Kalman-filter removal and Smith-predictor rewrite (see git history for `temp_controller.py`/`temp_controller_smith.py`). - [x] **FSM thresholds aren't configurable.** Moved into an optional `TempCtrl.Thresholds` config section (`HoldIdle`, `HoldHeat`, `IdleHeat`, `IdleHold`, `HeatHold`, `HeatIdle`), merged over `DEFAULT_THRESHOLDS` (now in `temp_controller_base.py`, formerly `tc_constants.py`) so existing configs without the section keep working unchanged. - [x] **matplotlib imported at module level in production code.** `temp_controller.py`, `temp_controller_smith.py`, and `kalman.py` used to `from matplotlib.pyplot import ...` just to support their `__main__` self-test plots. The plotting demos (and `kalman_eval.py`) moved to `scripts/demos/pid/demo_*.py`; production modules no longer import matplotlib. - [x] **Three Kalman filters share one tuning.** No longer applicable: `temp_controller_smith.py` was rewritten to drop Kalman filtering entirely (see below), so there's no shared tuning to split anymore. - [x] **`Pid.scale()` is a gain-scheduling hack, not anti-windup.** Fixed: removed `Pid.scale()`/`self.k` entirely. `Pid.process(err, d, scale=1.0)` now takes the gain multiplier as a plain per-call argument instead of mutable state, so there's nothing to go stale across a `reset()`. `temp_controller*.py` compute `hold_scale = 1.0/heatrate_soll_set if heatrate_soll_set > 0 else 1.0` themselves and pass it through `process_pid(theta_err, heatrate_err, hold_scale)` — the overshoot-compensation scheduling logic now lives entirely in the temp controller, not the generic `Pid` block. - [ ] **No automated tests.** `tests/components/pid/` was added once (stdlib `unittest`, no pytest) covering FSM transitions, anti-windup clamping, and Kalman convergence, but was removed again before the Kalman-filter removal/Smith rewrite, so none of the current `temp_controller*.py` behavior (backward-difference + low-pass filtered heat rate, the two-model Smith correction) has test coverage. This drives a physical heater — worth re-adding. - [ ] **`set_model_power` isn't defined on every controller, but `brewpi.py` wires it unconditionally.** `brewpi.py` always does `heater.set_on_changed("power_set", tc.set_model_power)` regardless of `Controller.pid_type`. Only `temp_controller_smith.py` (the Smith predictor) defines `set_model_power`; `temp_controller.py` (`"Normal"`) does not, so starting the server with `"pid_type": "Normal"` crashes at wiring time with `AttributeError: 'TempController' object has no attribute 'set_model_power'`. Either add a no-op `set_model_power` to `TempControllerBase`, or only wire it when the configured controller actually exposes a model to feed. - [ ] **Config access is unchecked `dict[key]` everywhere.** `params['Hold']`, `params['Td']`, etc., throughout, with no schema validation at load time. We already hit this bug class once (`config.json.sim`'s `gain`/`Model` nesting mismatch). A small schema/dataclass validation layer at config-load would surface errors immediately instead of mid-`__init__` — and would have caught the dead `TempCtrl.Kalman` / `Model.kn` / `Plant.kn` keys that used to sit unused in `config.json.templ`/`.sim` (since deleted) and the `Model.gain`/`Plant.gain` keys still doing the same in `config.json.sim` right now — `Pot` dropped `gain` entirely, see `components/plant/TODO.md`. - [ ] **`kalman.py` is now dead code in production.** Neither `temp_controller.py` nor `temp_controller_smith.py` uses `Kalman` anymore; the only remaining references are `scripts/demos/pid/demo_kalman.py` and `demo_kalman_eval.py`. Decide whether to keep it as a documented standalone filtering example or delete it along with the demos.