HeaterTask.on_changed_active() was never registered as a callback so
never fired; TcTask.recv() no longer needs to handle {Enable: ...}
since no client sends it after the override checkbox removal.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01DF16nV2ispNw1C9SbvqbRQ
Callbacks were registered inside the async on_process() coroutine,
meaning they weren't active until the event loop started ticking.
Moving them to __init__ ensures they're wired up at construction time.
Also removes remaining debug prints from the affected task files.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Tqxrk8uj4M3w3d3eXm3xK8
is_configured() (Smith's model plant params, only ever set once a Sud
loads) gates TcTask's call to tc.process() - the only place theta_ist/
heatrate_ist/heatrate_soll get updated and broadcast. Right after
server start, before any Sud has ever loaded, that left them frozen at
their __init__ defaults forever, so the GUI's Ist Temp/Rate and Soll
Rate displays never showed anything on connect. Mirror the raw sensor
reading through instead, with rates at 0 since there's no controller
output yet.
server/brewpi.py no longer pre-configures the real Pot's or Smith's model's
plant params at startup - there's no longer any generic baseline at all,
since the only source of truth is now a loaded Sud's own doc (applied via
tasks/sud.py's SudTask.apply_plant_params(), on Load and on every step).
Ambient temperature and PID gains stay configured at startup, since
they're independent of any Sud (global setting / hardware tuning, not
doc-derived).
Add Pot.is_configured() (already existed)/TempControllerBase.is_configured()/
TempController(Smith).is_configured(), and have tasks/pot.py's PotTask and
tasks/tempctrl.py's TcTask skip process() while not yet configured instead
of letting it raise - so plant and temp control are genuinely inert (not
crashing) until a Sud is loaded. "Normal" has no plant-model dependency,
so it stays active regardless.
Also refreshes README.md: removes stale tracer.py/.mat references (already
removed in an earlier commit), documents SudLogTask's JSON logs, the doc's
L/Td fields, and this inert-until-loaded behavior.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01DkkuG48uHFCGKe6dPSERFk
New TempControllerBase.enabled (default False) forces y=0 in
process_pid() when off, same mechanism as the existing cooling
override - the controller tries not to drive the heater at all.
tasks/tempctrl.py: new 'Enable' recv command and 'Enabled' broadcast
on the TempCtrl channel. tasks/sud.py: SudTask now enables the
controller on any non-IDLE/DONE Sud state and disables it (forcing
power back to 0) on IDLE/DONE, so automatic mode owns it for the
duration of a run and hands back manual control once it stops/finishes.
gui: new "Enabled" checkbox on the Manual tab's Controller group,
synced from the server; the temp/heatrate setpoint controls are
disabled whenever the controller itself is disabled.
on_temp_ist_changed/on_rate_ist_changed printed every update in
addition to forwarding it over the WebSocket, spamming stdout once
per controller tick.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>