Commit Graph
8 Commits
Author SHA1 Message Date
jens a1864a5257 log: route task/component status output through logging, not print()
AttributeChange (the common base of every ATask and component ABC) now
sets self.log = logging.getLogger(type(self).__name__), so components
no longer need to hand-type their own name into each message. Wired
logging.basicConfig() in server/brewpi.py with a bare "%(name)s:
%(message)s" formatter - Tee (see prior commit) still supplies the
"<date>T<time>:" prefix, so lines read "<date>T<time>:<component>:
<message>" without double-stamping, and third-party loggers
(websockets, asyncio) now get the same formatting for free.

Converted the print() call sites that were standing in for this in
tasks/ and components/ (leaving __main__ demo blocks and explicit
debug-dump helpers alone).
2026-07-10 22:00:04 +02:00
jensandClaude Sonnet 5 a19d2504fb stirrer: decode and report Pololu SMC status errors instead of guessing
Adds StatusError flags for the STATUS register and get_status_errors();
go() now reports if a fail-safe (safe-start violation or other error)
persists after GO instead of failing silently. _on_process uses the
same decoding to log any active error and only auto-recovers on a
safe-start violation, rather than the old narrow status & limit_status
heuristic.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01EU3NTwLygh8jkrnqPoHNXF
2026-07-07 19:36:11 +02:00
jensandClaude Sonnet 5 f20e617d81 feat: add connect/disconnect status for real heater/stirrer hardware
Heater and Stirrer can be real serial hardware (hendi, Pololu1376), but
there was no connection concept at all - the constructors opened the
port and crashed the whole server if the device was missing, with no
way to see connection status or firmware version and no way to
reconnect without a restart.

Adds an observable Connectable mixin (components/connectable.py) shared
by AHeater/AStirrer; real devices defer opening the serial port to an
explicit connect(), auto-connect on server startup, and surface
Connected/FirmwareVersion/Simulated plus manual Connect/Disconnect over
the web GUI. Heating/stirring and Sud Start are all gated on connection
state, and a disconnect mid-brew force-stops the run via the same path
as a manual Stop.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YaPLuRPpyjWcwhMvCvpHCL
2026-07-03 19:18:59 +02:00
jens 1bcabb0ccc added firmware info to hendi and motor driver 2026-07-02 16:33:37 +02:00
jens 0843f1d87a - Pololu1376: take enums as variable id
- stirrerPololu1376: Make for robust against motor cable plug
2021-08-12 20:13:47 +01:00
jens ebd5d4cd5e - added dignostic vars
- make print_vars a method
2021-08-12 09:48:06 +02:00
jens 71b5ac848f - refactored 2021-08-11 18:00:35 +02:00
jens 6196f944c6 - use new Pololu driver 2021-08-11 17:49:37 +02:00