Drop the now-stale "config.json.templ/.sim still carry dead
Model.kn/Plant.kn keys" note (they were deleted), note that Pot now
always starts at theta_amb (no separate initial-temp param) and that
dropping the gain (efficiency) factor entirely is a partial realism
regression, not just a fix. Point the config-validation item at the
gain key that's still dead in config.json.sim. Also update demo_sud.py
to match the Pot params Pot.__init__ actually reads.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
[Pot] - removed the gain (efficiency) factor and the separate
"theta" initial-temperature param; Pot now starts at theta_amb and
set_power()/get_power() operate on p_in directly. Added
set_ambient_temperature() for live ambient updates. Dropped the
now-unused "theta"/"gain" keys from Model/Plant in config.json.sim
and config.json.templ (also fixes a JSON syntax error in
config.json.templ: trailing commas left over after removing "gain"
made Model/Plant fail to parse).
[Sensor] - fix missing space in TempSensorSim.temperature()'s
offset/variance expression (cosmetic, no behavior change).
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
The unconditional p_loss/theta_amb/temp prints (left over from the
heat-loss-units fix) ran every tick, spamming stdout in both the
server and every demo script. Drop them and check off the matching
TODO.md item.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Both TODO.md backlogs and the README's architecture section still
described the Kalman-filter/heat-diffusion design that's since been
replaced by the delay-line Pot model and Kalman-free Smith predictor.
Check off the items that rewrite already fixed (heat-loss units,
transport delay vs. single-pole lag, three-Kalman-tuning), note how
the kn/sensor-noise item was resolved differently than proposed, and
add newly-spotted issues: brewpi.py wiring set_model_power
unconditionally (breaks pid_type "Normal"), kalman.py being dead code
in production, stale Kalman/kn keys in the config templates, and
debug print()s left in Pot.process().
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
tc_constants.py only held States and DEFAULT_THRESHOLDS, both used
exclusively by temp_controller_base.py and its subclasses; fold them
into temp_controller_base.py directly and drop the now-empty module.
Also drop heat_diffusion.py, unused since pot.py switched to the
delay-line model, and the matching dead import in pot.py.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
[brewpi] - drop trace vars for the dtheta_ist_* attributes removed
when temp_controller_smith.py dropped Kalman filtering
[Pot] - drop unused kn field (never read since the noise-injection
code that used it was dropped)
[GUI] - default WS connection to ws://localhost:8765
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Review of pot.py found a likely root cause for sim-vs-real control
mismatches: the heat-loss term carries the wrong units, masking
ambient cooling in simulation. Also notes the dropped sensor-noise
term, hardcoded ambient temp, and lag-vs-dead-time modeling gap.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>