The previous hotfix's disconnect()-on-comm-error path can now fire
during server/brewpi.py's own final best-effort hardware-release
cleanup (finally: block's heater.close()/stirrer.activate(False)),
which runs after the event loop has already stopped - previously
nothing about hardware teardown touched an AttributeChange-tracked
field, so this path was dormant. asyncio.create_task() there raises
RuntimeError: no running event loop, crashing the shutdown sequence.
Adds fire_and_forget() (tasks/task.py) - asyncio.create_task() that
silently drops the message instead of raising when there's no loop to
schedule on - and uses it for the Connected/FirmwareVersion broadcasts.
SudTask.check_connections() also now no-ops entirely without a running
loop, since self.sud.stop() cascades into further unguarded
create_task() calls (on_state_changed, heater_task.shutdown(), ...)
that a stopped loop can't help with anyway.
Reproduced and verified fixed directly against HeaterTask/HeaterHendi
with no event loop running (mirrors the exact server/brewpi.py
shutdown-time call path that crashed on the brewpi Pi).
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YaPLuRPpyjWcwhMvCvpHCL
Heater and Stirrer can be real serial hardware (hendi, Pololu1376), but
there was no connection concept at all - the constructors opened the
port and crashed the whole server if the device was missing, with no
way to see connection status or firmware version and no way to
reconnect without a restart.
Adds an observable Connectable mixin (components/connectable.py) shared
by AHeater/AStirrer; real devices defer opening the serial port to an
explicit connect(), auto-connect on server startup, and surface
Connected/FirmwareVersion/Simulated plus manual Connect/Disconnect over
the web GUI. Heating/stirring and Sud Start are all gated on connection
state, and a disconnect mid-brew force-stops the run via the same path
as a manual Stop.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YaPLuRPpyjWcwhMvCvpHCL
- Stirrer starts at speed 0 (was 50) so blades don't spin on connect
- Grain particles only levitate when stirrer is running
- Fire size driven by PowerSet (soll) instead of Power (ist)
- Split animation-play-state out of stirrer shorthand for reliable pausing
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01JLR2133M2PyjiYq584i2G7
Callbacks were registered inside the async on_process() coroutine,
meaning they weren't active until the event loop started ticking.
Moving them to __init__ ensures they're wired up at construction time.
Also removes remaining debug prints from the affected task files.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Tqxrk8uj4M3w3d3eXm3xK8