docs: record hendi remote-control lockout findings for firmware v1.12
Baseline for the planned firmware fix: reset/reconnect don't clear the ungraceful-disconnect lockout, only a physical power cycle does. Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01GpePKZiEZWbGo9HrfuML6U
This commit is contained in:
@@ -0,0 +1,35 @@
|
|||||||
|
# Hendi remote-control lockout findings
|
||||||
|
|
||||||
|
Firmware under test: **v1.12** (`getSoftwareVersion()` / `I?`+`V?` via
|
||||||
|
`components/actor/hendiCtrl.py`). Reproduced and verified on real hardware
|
||||||
|
using `scripts/hendi_ctrl_app.py`'s `--trigger-error-state`, `--reset` and
|
||||||
|
`--test-heater` flags.
|
||||||
|
|
||||||
|
## Trigger
|
||||||
|
|
||||||
|
Calling `remoteEnable(True)` (`R1`) and then disconnecting/exiting without a
|
||||||
|
matching `remoteEnable(False)` (`R0`) - i.e. an ungraceful disconnect while
|
||||||
|
remote control is enabled - puts the device into a locked-out state.
|
||||||
|
|
||||||
|
## Recovery attempts
|
||||||
|
|
||||||
|
| # | Recovery method | Mechanism | Result |
|
||||||
|
|---|---|---|---|
|
||||||
|
| 1 | `--reset` (toggle DTR/RTS reset line) | Soft reset via serial control lines, no power loss | **Fails** - `remoteEnable(True)` still returns `HendiException("Communication error")` on the next connection |
|
||||||
|
| 2 | `--reset` immediately followed by `--test-heater` in the *same* process/connection | Soft reset, then reuse the still-open serial connection | Succeeded once, but not reproducible across repeat isolated attempts - not a reliable recovery path |
|
||||||
|
| 3 | Physical power cycle (device knob) | Full power-off/on of the unit | **Recovers** - `remoteEnable(True)` succeeds immediately afterward, heater sweep runs cleanly |
|
||||||
|
|
||||||
|
## Symptom while locked out
|
||||||
|
|
||||||
|
- `I?` / `V?` (software identifier/version queries) still respond normally.
|
||||||
|
- `R1` (`remoteEnable(True)`) fails with a communication error - this is the
|
||||||
|
only observed symptom, and it blocks any command path that needs remote
|
||||||
|
control enabled (e.g. `--test-heater`).
|
||||||
|
|
||||||
|
## Conclusion
|
||||||
|
|
||||||
|
On firmware v1.12, only a physical power cycle clears the lockout; neither a
|
||||||
|
serial soft-reset nor a fresh serial reconnect does. This is the behavior the
|
||||||
|
planned firmware fix should address - a graceful-disconnect timeout, an
|
||||||
|
explicit unlock command, or making the DTR/RTS reset line actually clear the
|
||||||
|
lockout flag.
|
||||||