fix: heater task permanently died after a mid-brew unplug, never recovered
Root cause (from the brewpi Pi's log): HendiCtrl.disconnect() only caught HendiException (a protocol-level NAK), but a genuine unplug fails deep inside pyserial itself - flushInput()/readline() raise termios.error/OSError on the now-dead fd. That escaped disconnect() uncaught (skipping self.ser.close() too), then kept propagating up through every caller that invoked disconnect() from its own except handler (HeaterHendi.process()/activate(), AHeater.open()'s context-manager exit), all the way out of HeaterTask.on_process()'s coroutine entirely. Nothing restarts a dead ATask, so the heater's process()/duty-cycle loop was gone for the rest of the process's life - reconnecting afterward changed `connected` back to True but nothing was left running to ever call process() again. Fixes: - HendiCtrl.disconnect() now catches broadly and always closes the port, matching Pololu1376.disconnect()'s already-correct pattern. - HeaterTask/StirrerTask.on_process() gain an outer retry loop as a safety net: even an unanticipated exception now logs, marks disconnected, and re-enters rather than permanently killing the task. Verified by reproducing the exact failure (comm error raising a raw OSError, not HendiException) against a fake device - the task now survives and resumes process()ing once reconnected. Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01YaPLuRPpyjWcwhMvCvpHCL
This commit is contained in:
@@ -213,9 +213,23 @@ class HendiCtrl:
|
||||
if self.ser.is_open:
|
||||
try:
|
||||
self.remoteEnable(False)
|
||||
except HendiException:
|
||||
except Exception:
|
||||
# Not just HendiException (a protocol-level NAK) - a genuine
|
||||
# unplug fails deep inside pyserial itself (termios.error/
|
||||
# OSError from flushInput()/readline() on a dead fd), and
|
||||
# disconnect() must never let that escape: every caller here
|
||||
# (HeaterHendi.process()/activate()'s own except handlers,
|
||||
# AHeater.open()'s context-manager exit) calls disconnect()
|
||||
# specifically to recover from a comm failure, so if this
|
||||
# raises too it propagates all the way out of HeaterTask's
|
||||
# on_process() and permanently kills that task's loop - the
|
||||
# device then never gets process()'d again even after a
|
||||
# later successful reconnect.
|
||||
pass
|
||||
try:
|
||||
self.ser.close()
|
||||
except Exception:
|
||||
pass
|
||||
self.ser.close()
|
||||
self.sw_id = None
|
||||