Check off theta_amb backlog item now that it's config-driven
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
This commit is contained in:
@@ -27,11 +27,16 @@ the current `delay`-line rewrite of `Pot`.
|
|||||||
that nothing reads anymore — harmless but worth deleting (see
|
that nothing reads anymore — harmless but worth deleting (see
|
||||||
`components/pid/TODO.md`'s config-validation item).
|
`components/pid/TODO.md`'s config-validation item).
|
||||||
|
|
||||||
- [ ] **`theta_amb` is hardcoded, not configured.** Still true —
|
- [x] **`theta_amb` is hardcoded, not configured.** Fixed: added a
|
||||||
`brewpi.py`: `pot = Pot(DT, pot_params, 20)` passes a literal `20`
|
top-level `ambient_temperature` key to `config.json`(`.templ`/`.sim`);
|
||||||
instead of reading it from config or a live ambient sensor. Real
|
`brewpi.py` reads it once and passes it to both the real `Pot` and
|
||||||
ambient temperature drifts and is never modeled as a disturbance, so
|
(via a new `theta_amb` param) `temp_controller_smith.py`'s internal
|
||||||
the controller's robustness to it is untested.
|
models, so the Smith predictor's model matches the real plant's
|
||||||
|
assumed ambient instead of silently defaulting to 20. Real ambient
|
||||||
|
temperature still isn't modeled as a *drifting* disturbance (it's a
|
||||||
|
static config value, not a live sensor reading), so robustness to
|
||||||
|
ambient drift remains untested — that part of the original concern
|
||||||
|
stands.
|
||||||
|
|
||||||
- [ ] **No actuator/process realism.** Partially improved: `process()`
|
- [ ] **No actuator/process realism.** Partially improved: `process()`
|
||||||
now clamps `self.temp` to `min(100, ...)` (won't simulate past
|
now clamps `self.temp` to `min(100, ...)` (won't simulate past
|
||||||
|
|||||||
Reference in New Issue